<scp>Finite Element</scp> analysis and experimental study of static performance of multi‐<scp>CFRP</scp> tendon composite anchorage system

Abstract A novel composite anchorage with dispersed arrangement of carbon fiber‐reinforced polymer (CFRP) tendons was proposed. The bonding length and constraint ratio of the dispersed‐tendon composite anchorage were determined by numerical simulation. Six groups of multi‐CFRP tendon composite anchorage systems (MTCAS) were tested to investigate their static performance. The axial force dispersion coefficient c v and relative slip ratio coefficient δ were proposed to evaluate the static performance of the MTCAS with variables, including pre‐tension load, the inner inclination angle of the sleeve and the modified bonding medium. Results demonstrated that increasing the bonding length and restraint ratio of steel sleeve could improve the stress state of tendon in the anchorage. The anchorage with a bonding length of 280 mm and a constraint ratio of the sleeve of 0.90 can reliably anchor multiple CFRP tendons arranged in a dispersed arrangement. An inner inclination angle of 3.1° of the sleeve can be adopted on the premise that strength utilization ratio is guaranteed and anchorage diameter meets the requirements. An adequate pre‐tension load can reduce the slips of tendons, and the recommended pre‐tension load value should not exceed 0.7 F ptk . The 0.25% basalt fiber‐modified epoxy resin anchorage obtained the highest strength utilization ratio. Highlights A novel composite anchorage with dispersed carbon fiber‐reinforced polymer tendons was designed. New mechanical parameters evaluating anchorage performance were proposed. Basalt fiber (BF)‐modified epoxy resin (ER) can improve anchoring performance. The 0.25% BF‐modified ER anchorage obtained the highest strength utilization ratio. Pre‐tension load should not exceed 0.7 times the theoretical tensile load.

Authors

Institutions

Publication Details

Journal
Polymer Composites
Published
2024-08-16
DOI
https://doi.org/10.1002/pc.28918
Citations
1
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.27

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite Element analysis and experimental study of static performance of multi‐CFRP tendon composite anchorage system

Kuihua Mei, Wenke Jia, Xue Li, Yuanzhi Wang et al.
1 citations
Polymer Composites
Structural Behavior of Reinforced Concrete
0.27
article

Finite Element analysis and experimental study of static performance of multi‐CFRP tendon composite anchorage system

Kuihua Mei, Wenke Jia, Xue Li, Yuanzhi Wang, Shiyu Sun
article en
1 citations

Abstract

Abstract A novel composite anchorage with dispersed arrangement of carbon fiber‐reinforced polymer (CFRP) tendons was proposed. The bonding length and constraint ratio of the dispersed‐tendon composite anchorage were determined by numerical simulation. Six groups of multi‐CFRP tendon composite anchorage systems (MTCAS) were tested to investigate their static performance. The axial force dispersion coefficient c v and relative slip ratio coefficient δ were proposed to evaluate the static performance of the MTCAS with variables, including pre‐tension load, the inner inclination angle of the sleeve and the modified bonding medium. Results demonstrated that increasing the bonding length and restraint ratio of steel sleeve could improve the stress state of tendon in the anchorage. The anchorage with a bonding length of 280 mm and a constraint ratio of the sleeve of 0.90 can reliably anchor multiple CFRP tendons arranged in a dispersed arrangement. An inner inclination angle of 3.1° of the sleeve can be adopted on the premise that strength utilization ratio is guaranteed and anchorage diameter meets the requirements. An adequate pre‐tension load can reduce the slips of tendons, and the recommended pre‐tension load value should not exceed 0.7 F ptk . The 0.25% basalt fiber‐modified epoxy resin anchorage obtained the highest strength utilization ratio. Highlights A novel composite anchorage with dispersed carbon fiber‐reinforced polymer tendons was designed. New mechanical parameters evaluating anchorage performance were proposed. Basalt fiber (BF)‐modified epoxy resin (ER) can improve anchoring performance. The 0.25% BF‐modified ER anchorage obtained the highest strength utilization ratio. Pre‐tension load should not exceed 0.7 times the theoretical tensile load.

Polymer CompositesVol. 45(18)
Chang'an University (CN), Zhejiang Water Conservancy and Hydropower Survey and Design Institute (CN), Guzhou Transportation Planning Survey & Design Academe (China) (CN)
National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 45%
Structural Behavior of Reinforced Concrete
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.