Detection of Subtle ECG Changes Despite Superimposed Artifacts by Different Machine Learning Algorithms

Analyzing electrocardiographic (ECG) signals is crucial for evaluating heart function and diagnosing cardiac pathology. Traditional methods for detecting ECG changes often rely on offline analysis or subjective visual inspection, which may overlook subtle variations, particularly in the case of artifacts. In this theoretical, proof-of-concept study, we investigated the potential of five different machine learning algorithms [random forests (RFs), gradient boosting methods (GBMs), deep neural networks (DNNs), an ensemble learning technique, as well as logistic regression] to detect subtle changes in the morphology of synthetically generated ECG beats despite artifacts. Following the generation of a synthetic ECG beat using the standardized McSharry algorithm, the baseline ECG signal was modified by changing the amplitude of different ECG components by 0.01–0.06 mV. In addition, a Gaussian jitter of 0.1–0.3 mV was overlaid to simulate artifacts. Five different machine learning algorithms were then applied to detect differences between the modified ECG beats. The highest discriminatory potency, as assessed by the discriminatory accuracy, was achieved by RFs and GBMs (accuracy of up to 1.0), whereas the least accurate results were obtained by logistic regression (accuracy approximately 10% less). In a second step, a feature importance algorithm (Boruta) was used to discriminate which signal parts were responsible for difference detection. For all comparisons, only signal components that had been modified in advance were used for discretion, demonstrating that the RF model focused on the appropriate signal elements. Our findings highlight the potential of RFs and GBMs as valuable tools for detecting subtle ECG changes despite artifacts, with implications for enhancing clinical diagnosis and monitoring. Further studies are needed to validate our findings with clinical data.

Authors

Institutions

Publication Details

Journal
Algorithms
Published
2024-08-16
DOI
https://doi.org/10.3390/a17080360
Citations
4
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of Subtle ECG Changes Despite Superimposed Artifacts by Different Machine Learning Algorithms

Jens Meier, Christoph Mörtl, Matthias Noitz, Ulrich Bodenhofer et al.
4 citations
Algorithms
ECG Monitoring and Analysis
1.61
article

Detection of Subtle ECG Changes Despite Superimposed Artifacts by Different Machine Learning Algorithms

Jens Meier, Christoph Mörtl, Matthias Noitz, Ulrich Bodenhofer, Carl Böck, Christoph Mahringer, Martin W. Dünser
article en
4 citations

Abstract

Analyzing electrocardiographic (ECG) signals is crucial for evaluating heart function and diagnosing cardiac pathology. Traditional methods for detecting ECG changes often rely on offline analysis or subjective visual inspection, which may overlook subtle variations, particularly in the case of artifacts. In this theoretical, proof-of-concept study, we investigated the potential of five different machine learning algorithms [random forests (RFs), gradient boosting methods (GBMs), deep neural networks (DNNs), an ensemble learning technique, as well as logistic regression] to detect subtle changes in the morphology of synthetically generated ECG beats despite artifacts. Following the generation of a synthetic ECG beat using the standardized McSharry algorithm, the baseline ECG signal was modified by changing the amplitude of different ECG components by 0.01–0.06 mV. In addition, a Gaussian jitter of 0.1–0.3 mV was overlaid to simulate artifacts. Five different machine learning algorithms were then applied to detect differences between the modified ECG beats. The highest discriminatory potency, as assessed by the discriminatory accuracy, was achieved by RFs and GBMs (accuracy of up to 1.0), whereas the least accurate results were obtained by logistic regression (accuracy approximately 10% less). In a second step, a feature importance algorithm (Boruta) was used to discriminate which signal parts were responsible for difference detection. For all comparisons, only signal components that had been modified in advance were used for discretion, demonstrating that the RF model focused on the appropriate signal elements. Our findings highlight the potential of RFs and GBMs as valuable tools for detecting subtle ECG changes despite artifacts, with implications for enhancing clinical diagnosis and monitoring. Further studies are needed to validate our findings with clinical data.

AlgorithmsVol. 17(8)
Johannes Kepler University of Linz (AT), Kepler Universitätsklinikum (AT), University of Applied Sciences Upper Austria (AT)
Reduced inequalities
Openalex Percentile: Top 15%
ECG Monitoring and Analysis
1.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.