Comparative analysis of delivered and planned doses in target volumes for lung stereotactic ablative radiotherapy
Evaluation of the dose delivered to patients with NSCLC treated with SABR using ACTs confirmed that the prescribed dose was accurately delivered to the ITV. However, for the PTV, certain ACT cases characterised by high HI deviations from the original plan demonstrated variations in the delivered dose. These variations may potentially arise from factors such as patient setup during treatment, as suggested by the statistical analyses of the parameters obtained from the dose evaluation process.
Authors
- Geum Bong Yu (ORCID: https://orcid.org/0000-0001-7435-2963)
- Hak Jae Kim (ORCID: https://orcid.org/0000-0003-3602-2263)
- Seonghee Kang (ORCID: https://orcid.org/0000-0002-1153-6842)
- Seungwan Lee (ORCID: https://orcid.org/0000-0002-5875-9971)
- Jung In Kim (ORCID: https://orcid.org/0000-0003-4892-7318)
- Chang Heon Choi (ORCID: https://orcid.org/0000-0003-0449-1372)
Institutions
- Seoul National University (KR)
- Konyang University (KR)
- New Generation University College (ET)
- Seoul National University Hospital (KR)
- National University College (PR)
Publication Details
- Journal
- Radiation Oncology
- Published
- 2024-08-16
- DOI
- https://doi.org/10.1186/s13014-024-02505-7
- Citations
- 1
- Primary Topic
- Advanced Radiotherapy Techniques
- Type
- article
- Field-Weighted Citation Impact
- 0.61
Funders
- National Research Foundation
- National Research Foundation of Korea
- Ministry of Science and ICT, South Korea