An FPGA-Based 64-Channel Readout Electronics for High-Resolution TOF-PET Detectors
Field programmable logic array (FPGA)-based readout electronics has shown its capability of channel-by-channel signal readout for time-of-flight positron emission tomography (TOF-PET) detectors. However, for detectors that rely on light sharing to achieve subpixel resolution, the high-linear measurement dynamic range of the readout electronics is highly required. In this article, the problems with dynamic range in our previously proposed FPGA-based fast linear discharge circuit are investigated and corresponding methods are proposed to enhance its small signal measurement capability and improve the timing performance as well. A practical 64-channel TOF-PET detector module was constructed and evaluated. The readout electronics test results demonstrated a 240x measurement dynamic range with 99.5% conversion linearity. In the case that the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$8\times 8$ </tex-math></inline-formula> silicon photomultiplier (SiPM) array in the detector combines with an <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$8\times 8$ </tex-math></inline-formula> LYSO crystal (each <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$3.2\times 3.2\times 10$ </tex-math></inline-formula> mm3) array, the average energy and coincidence time resolution of the detector are measured as 10.68% (511 keV) and 364.9 ps, respectively. To demonstrate the benefit of large dynamic range to high-resolution detectors, the crystal array in the detector was replaced by a <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$24\times 24$ </tex-math></inline-formula> LYSO array (each <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1.04\times 1.04\times 15$ </tex-math></inline-formula> mm3) and achieved 1-mm resolution. The test results confirm that the proposed FPGA-based readout circuit is practical for laboratory instrumentation
Authors
- Xiaoguang Kong (ORCID: https://orcid.org/0000-0002-6211-5052)
- Xiang Zhang (ORCID: https://orcid.org/0009-0006-6182-9359)
- M. Wang (ORCID: https://orcid.org/0000-0002-6151-0202)
- Yonggang Wang (ORCID: https://orcid.org/0000-0002-4204-0073)
Institutions
- University of Science and Technology of China (CN)
- Hefei University (CN)
Publication Details
- Journal
- IEEE Transactions on Radiation and Plasma Medical Sciences
- Published
- 2024-08-16
- DOI
- https://doi.org/10.1109/trpms.2024.3443831
- Citations
- 2
- Primary Topic
- Medical Imaging Techniques and Applications
- Type
- article
- Field-Weighted Citation Impact
- 0.81
Funders
- National Natural Science Foundation of China