The application of blood flow sound contrastive learning to predict arteriovenous graft stenosis of patients with hemodialysis

End-stage kidney disease (ESKD) presents a significant public health challenge, with hemodialysis (HD) remaining one of the most prevalent kidney replacement therapies. Ensuring the longevity and functionality of arteriovenous accesses is challenging for HD patients. Blood flow sound, which contains valuable information, has often been neglected in the past. However, machine learning offers a new approach, leveraging data non-invasively and learning autonomously to match the experience of healthcare professionas. This study aimed to devise a model for detecting arteriovenous grafts (AVGs) stenosis. A smartphone stethoscope was used to record the sound of AVG blood flow at the arterial and venous sides, with each recording lasting one minute. The sound recordings were transformed into mel spectrograms, and a 14-layer convolutional neural network (CNN) was employed to detect stenosis. The CNN comprised six convolution blocks with 3x3 kernel mapping, batch normalization, and rectified linear unit activation function. We applied contrastive learning to train the pre-training audio neural networks model with unlabeled data through self-supervised learning, followed by fine-tuning. In total, 27,406 dialysis session blood flow sounds were documented, including 180 stenosis blood flow sounds. Our proposed framework demonstrated a significant improvement (p<0.05) over training from scratch and a popular pre-trained audio neural networks (PANNs) model, achieving an accuracy of 0.9279, precision of 0.8462, and recall of 0.8077, compared to previous values of 0.8649, 0.7391, and 0.6538. This study illustrates how contrastive learning with unlabeled blood flow sound data can enhance convolutional neural networks for detecting AVG stenosis in HD patients.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-08-16
DOI
https://doi.org/10.1371/journal.pone.0308385
Citations
2
Primary Topic
Phonocardiography and Auscultation Techniques
Type
article
Field-Weighted Citation Impact
0.84

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The application of blood flow sound contrastive learning to predict arteriovenous graft stenosis of patients with hemodialysis

Phang‐Lang Chen, Yi-Ren Yeh, Hugo You‐Hsien Lin, Yen-Jung Kuo et al.
2 citations
PLoS ONE
Phonocardiography and Auscultation Techniques
0.84
article

The application of blood flow sound contrastive learning to predict arteriovenous graft stenosis of patients with hemodialysis

Phang‐Lang Chen, Yi-Ren Yeh, Hugo You‐Hsien Lin, Yen-Jung Kuo, Sheng‐Wen Niu, I‐Ching Kuo, Kai-Chieh Yang, Juan-Wei Xu, T. Shien, Hsuan‐Fu Kuo
article en
2 citations

Abstract

End-stage kidney disease (ESKD) presents a significant public health challenge, with hemodialysis (HD) remaining one of the most prevalent kidney replacement therapies. Ensuring the longevity and functionality of arteriovenous accesses is challenging for HD patients. Blood flow sound, which contains valuable information, has often been neglected in the past. However, machine learning offers a new approach, leveraging data non-invasively and learning autonomously to match the experience of healthcare professionas. This study aimed to devise a model for detecting arteriovenous grafts (AVGs) stenosis. A smartphone stethoscope was used to record the sound of AVG blood flow at the arterial and venous sides, with each recording lasting one minute. The sound recordings were transformed into mel spectrograms, and a 14-layer convolutional neural network (CNN) was employed to detect stenosis. The CNN comprised six convolution blocks with 3x3 kernel mapping, batch normalization, and rectified linear unit activation function. We applied contrastive learning to train the pre-training audio neural networks model with unlabeled data through self-supervised learning, followed by fine-tuning. In total, 27,406 dialysis session blood flow sounds were documented, including 180 stenosis blood flow sounds. Our proposed framework demonstrated a significant improvement (p<0.05) over training from scratch and a popular pre-trained audio neural networks (PANNs) model, achieving an accuracy of 0.9279, precision of 0.8462, and recall of 0.8077, compared to previous values of 0.8649, 0.7391, and 0.6538. This study illustrates how contrastive learning with unlabeled blood flow sound data can enhance convolutional neural networks for detecting AVG stenosis in HD patients.

PLoS ONEVol. 19(8)
Dartmouth College (US), National Kaohsiung Normal University (TW), Kaohsiung Medical University (TW), University of California, Irvine (US), Kaohsiung Medical University Chung-Ho Memorial Hospital (TW), Kaohsiung Municipal Ta-Tung Hospital (TW), Kura Oncology (United States) (US)
Kaohsiung Municipal Ta-Tung Hospital, National Science and Technology Council
Good health and well-being
Openalex Percentile: Top 25%
Phonocardiography and Auscultation Techniques
0.84
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.