Numerical analysis and evaluation of a tropical classroom for thermal comfort, indoor air quality, and energy consumption using ventilation with air-to-air total heat recovery system (MemHEX)

Lecture rooms in the Philippines often experience unfavourable temperatures and elevated carbon dioxide (CO2) concentrations, impacting the well-being, health, and learning efficiency of both students and educators. This research seeks to evaluate the thermal comfort, indoor air quality, and energy usage in a standard Philippine lecture room by implementing a membrane-type total heat exchanger (MemHEX). The research used computational fluid dynamics (CFD) simulations, which were validated by field measurements and showed the effectiveness of the MemHEX. Energy consumption was modelled using EnergyPlus to compare potential impacts of various ventilation approaches. Room temperature and humidity fall short of thermal comfort standards, suggesting the need for a higher-capacity air conditioning unit (ACU). Average CO2 concentration exceeds 1000 ppm, signalling a demand for ventilation. Post-MemHEX installation, temperature and humidity slightly rise with increased air changes per hour (ACH), introducing warm outdoor air. Indoor air quality improves with rising ACH, reducing CO2 levels by exchanging fresh outdoor air. Comparing mechanical ventilation and MemHEX reveals MemHEX as more energy-efficient, maintaining better indoor conditions. These findings provide valuable insights for the field of research by demonstrating the feasibility and benefits of using MemHEX to improve the indoor environment and energy efficiency of a typical Philippine classroom.

Authors

Institutions

Publication Details

Journal
Advances in Building Energy Research
Published
2024-08-16
DOI
https://doi.org/10.1080/17512549.2024.2386552
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical analysis and evaluation of a tropical classroom for thermal comfort, indoor air quality, and energy consumption using ventilation with air-to-air total heat recovery system (MemHEX)

Napoleon Enteria, Aaron John A. Rondina, Roldan P. Cuizon, Jethro Vince I. Solomon
1 citations
Advances in Building Energy Research
Building Energy and Comfort Optimization
0.27
article

Numerical analysis and evaluation of a tropical classroom for thermal comfort, indoor air quality, and energy consumption using ventilation with air-to-air total heat recovery system (MemHEX)

Napoleon Enteria, Aaron John A. Rondina, Roldan P. Cuizon, Jethro Vince I. Solomon
article en
1 citations

Abstract

Lecture rooms in the Philippines often experience unfavourable temperatures and elevated carbon dioxide (CO2) concentrations, impacting the well-being, health, and learning efficiency of both students and educators. This research seeks to evaluate the thermal comfort, indoor air quality, and energy usage in a standard Philippine lecture room by implementing a membrane-type total heat exchanger (MemHEX). The research used computational fluid dynamics (CFD) simulations, which were validated by field measurements and showed the effectiveness of the MemHEX. Energy consumption was modelled using EnergyPlus to compare potential impacts of various ventilation approaches. Room temperature and humidity fall short of thermal comfort standards, suggesting the need for a higher-capacity air conditioning unit (ACU). Average CO2 concentration exceeds 1000 ppm, signalling a demand for ventilation. Post-MemHEX installation, temperature and humidity slightly rise with increased air changes per hour (ACH), introducing warm outdoor air. Indoor air quality improves with rising ACH, reducing CO2 levels by exchanging fresh outdoor air. Comparing mechanical ventilation and MemHEX reveals MemHEX as more energy-efficient, maintaining better indoor conditions. These findings provide valuable insights for the field of research by demonstrating the feasibility and benefits of using MemHEX to improve the indoor environment and energy efficiency of a typical Philippine classroom.

Advances in Building Energy ResearchVol. 18(5)
Mindanao State University – Iligan Institute of Technology (PH)
Affordable and clean energy
Openalex Percentile: Top 45%
Building Energy and Comfort Optimization
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical analysis and evaluation of a tropical classroom for thermal comfort, indoor air quality, and energy consumption using ventilation with air-to-air total heat recovery system (MemHEX) — Napoleon Enteria, Aaron John A. Rondina, et al. · Advances in Building Energy Research (2024) | TGRS Research Map | TGRS