Research and application of SPR sensor membrane layer structure improvement

In this study, by redesigning the membrane layer structure of the traditional Kretschmann model of the surface plasmon resonance sensor, the problem of small measurement range of the solution concentration of the original structure and the reduced sensitivity of the sensor when measuring liquids with higher concentration was solved. In this paper, the transfer matrix method was adopted to calculate the attenuated total reflection intensity, and the surface plasmon resonance curve was obtained using the angular modulation method, and its feasibility was verified by simulation. The final experimental results show that for common transparent liquids such as NaCl solution, glucose solution, sucrose solution, etc. The membrane layer structure proposed in this paper can expand the originally small concentration measurement range to a full concentration range measurement, which is very effective for expanding the measurement range.

Authors

Institutions

Publication Details

Published
2024-08-16
DOI
https://doi.org/10.1117/12.3040103
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research and application of SPR sensor membrane layer structure improvement

Yingping Yang, Quan Long, Wenqiong Zhang, Chen Mengwei et al.
Advanced Fiber Optic Sensors
article

Research and application of SPR sensor membrane layer structure improvement

Yingping Yang, Quan Long, Wenqiong Zhang, Chen Mengwei, Yi Yan, Pengyang An
article en

Abstract

In this study, by redesigning the membrane layer structure of the traditional Kretschmann model of the surface plasmon resonance sensor, the problem of small measurement range of the solution concentration of the original structure and the reduced sensitivity of the sensor when measuring liquids with higher concentration was solved. In this paper, the transfer matrix method was adopted to calculate the attenuated total reflection intensity, and the surface plasmon resonance curve was obtained using the angular modulation method, and its feasibility was verified by simulation. The final experimental results show that for common transparent liquids such as NaCl solution, glucose solution, sucrose solution, etc. The membrane layer structure proposed in this paper can expand the originally small concentration measurement range to a full concentration range measurement, which is very effective for expanding the measurement range.

Wuhan University of Technology (CN), Systems Engineering Society of China (CN)
Openalex Percentile: Top 90%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.