Study on measurement method of high-temperature CO gas concentration based on TDLAS technology

The combustion of industrial furnace is an indispensable part of metal smelting and industrial power generation. In order to solve the problem of full combustion of coal in the furnace, it is necessary to accurately control the CO concentration in the industrial furnace. In the high temperature and high pressure environment of the industrial furnace, we choose the direct absorption spectroscopy method in the tunable semiconductor laser absorption spectroscopy technology to measure the CO concentration. In this paper, a high temperature blackbody furnace is used to simulate the high temperature and pressure environment in an industrial furnace, direct absorption spectrometry is used to measure the concentration of 5000ppm CO gas in 100℃-1100℃ environment. When the temperature in the blackbody furnace is 100℃-600℃, the relative error of experimental measurement is controlled within 10%; When the temperature exceeds 700℃, the relative error of measurement exceeds 20%, the measurement error is large, which can not meet the requirements of industrial application measurement accuracy.

Authors

Institutions

Publication Details

Published
2024-08-16
DOI
https://doi.org/10.1117/12.3040005
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on measurement method of high-temperature CO gas concentration based on TDLAS technology

Fan Zhang, L Zhang, Wei Song, Xinbing Chen et al.
Spectroscopy and Laser Applications
article

Study on measurement method of high-temperature CO gas concentration based on TDLAS technology

Fan Zhang, L Zhang, Wei Song, Xinbing Chen, Haibin Wu
article en

Abstract

The combustion of industrial furnace is an indispensable part of metal smelting and industrial power generation. In order to solve the problem of full combustion of coal in the furnace, it is necessary to accurately control the CO concentration in the industrial furnace. In the high temperature and high pressure environment of the industrial furnace, we choose the direct absorption spectroscopy method in the tunable semiconductor laser absorption spectroscopy technology to measure the CO concentration. In this paper, a high temperature blackbody furnace is used to simulate the high temperature and pressure environment in an industrial furnace, direct absorption spectrometry is used to measure the concentration of 5000ppm CO gas in 100℃-1100℃ environment. When the temperature in the blackbody furnace is 100℃-600℃, the relative error of experimental measurement is controlled within 10%; When the temperature exceeds 700℃, the relative error of measurement exceeds 20%, the measurement error is large, which can not meet the requirements of industrial application measurement accuracy.

Anhui University (CN)
Affordable and clean energy
Openalex Percentile: Top 90%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on measurement method of high-temperature CO gas concentration based on TDLAS technology — Fan Zhang, L Zhang, et al. · (2024) | TGRS Research Map | TGRS