Research on 2 μm laser based on a novel step concentration Tm: YAG crystal

This study employs step concentration technology to significantly reduce the severe thermal effects experienced by Tm: YAG crystals under high-power pumping. Firstly, the thermal distribution and thermal stress of Tm: YAG crystals with three different step concentrations are simulated respectively. It has been observed that the thermal conduction and distribution within the crystal vary with the concentration and length of the crystal. In the experiment, the output performance of LD-pumped Tm: YAG lasers with three different step concentrations was compared. In the continuous operation, the measured slope efficiencies were 35.34 %, 38.34 %, and 40.82 %, respectively. In the Q-switching operation, the slope efficiencies were 10.32 %, 10.87 %, and 12.56 % at the repetition frequency of 300 Hz, and the beam quality factor M2 was 1.63,1.52 and 1.46, respectively.

Authors

Institutions

Publication Details

Published
2024-08-16
DOI
https://doi.org/10.1117/12.3040043
Primary Topic
Solid State Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on 2 μm laser based on a novel step concentration Tm: YAG crystal

Junyang Dong, Chunting Wu, Kuan Li, Chao Niu
Solid State Laser Technologies
article

Research on 2 μm laser based on a novel step concentration Tm: YAG crystal

Junyang Dong, Chunting Wu, Kuan Li, Chao Niu
article en

Abstract

This study employs step concentration technology to significantly reduce the severe thermal effects experienced by Tm: YAG crystals under high-power pumping. Firstly, the thermal distribution and thermal stress of Tm: YAG crystals with three different step concentrations are simulated respectively. It has been observed that the thermal conduction and distribution within the crystal vary with the concentration and length of the crystal. In the experiment, the output performance of LD-pumped Tm: YAG lasers with three different step concentrations was compared. In the continuous operation, the measured slope efficiencies were 35.34 %, 38.34 %, and 40.82 %, respectively. In the Q-switching operation, the slope efficiencies were 10.32 %, 10.87 %, and 12.56 % at the repetition frequency of 300 Hz, and the beam quality factor M2 was 1.63,1.52 and 1.46, respectively.

Changchun University of Science and Technology (CN)
Openalex Percentile: Top 90%
Solid State Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.