Analysis and research on acceleration measurement methods for indoor large length standard devices

The indoor long length standard device is an important large-size measuring standard device, which has an acceleration and deceleration process during the starting and stopping stages of the slide. Studying the acceleration of the indoor long length standard device is of great physical significance for understanding its operating rules. In the article, a laser tracker was used to study the acceleration of indoor large length standards. Through data analysis using a laser tracker at equal sampling frequencies of 50Hz and 100Hz, some conclusions were drawn as follows: the acceleration value significantly increases when the measurement frequency of the laser tracker is increased. The maximum acceleration at 50Hz is 579.75 mm/s<sup>2</sup>, and the maximum acceleration at 100Hz is 920 mm/s<sup>2</sup>. After the acceleration phase is completed, the sliding table enters a constant speed phase, and the data oscillates in a zigzag pattern with zero values. After the deceleration phase is completed, the acceleration value of the sliding table steadily approaches zero.

Authors

Institutions

Publication Details

Published
2024-08-16
DOI
https://doi.org/10.1117/12.3035491
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and research on acceleration measurement methods for indoor large length standard devices

Fei Lv, Chang’an Hu, Li Li, Chengyi zhou et al.
Advanced Fiber Optic Sensors
article

Analysis and research on acceleration measurement methods for indoor large length standard devices

Fei Lv, Chang’an Hu, Li Li, Chengyi zhou, Xingxing Li, Baoquan Hu
article en

Abstract

The indoor long length standard device is an important large-size measuring standard device, which has an acceleration and deceleration process during the starting and stopping stages of the slide. Studying the acceleration of the indoor long length standard device is of great physical significance for understanding its operating rules. In the article, a laser tracker was used to study the acceleration of indoor large length standards. Through data analysis using a laser tracker at equal sampling frequencies of 50Hz and 100Hz, some conclusions were drawn as follows: the acceleration value significantly increases when the measurement frequency of the laser tracker is increased. The maximum acceleration at 50Hz is 579.75 mm/s<sup>2</sup>, and the maximum acceleration at 100Hz is 920 mm/s<sup>2</sup>. After the acceleration phase is completed, the sliding table enters a constant speed phase, and the data oscillates in a zigzag pattern with zero values. After the deceleration phase is completed, the acceleration value of the sliding table steadily approaches zero.

National Institute of Measurement and Testing Technology (CN), Xi’an International University (CN), Chengdu Normal University (CN)
Affordable and clean energy
Openalex Percentile: Top 90%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.