Nondestructive automatic detection of bregma and lambda points in rodent skull anatomy images

Based on an open-source image set, this study calculated the relative positional relationships between the eyes and the bregma and lambda points, using the nose tip as a reference point. We found that the correlation coefficients were as high as 0.942 and 0.935, respectively. Leveraging these findings, we fitted linear regression equations that can estimate the locations of the bregma and lambda points based on eye positions, with theoretical errors of 0.35mm and 0.57mm, respectively. Additionally, an automatic recognition algorithm for the nose tip and eyes was designed using openCV and YOLOV5, enabling automatic localization of the bregma and lambda points. Upon validation, the actual recognition errors of this method were 0.41mm and 0.66mm, respectively, demonstrating high precision. This noninvasive and straightforward automatic recognition approach not only effectively reduces surgical trauma to animals but also avoids the precision errors associated with manual positioning, offering new possibilities for the clinical application of brain-computer interface technology.

Authors

Institutions

Publication Details

Published
2024-08-16
DOI
https://doi.org/10.1117/12.3035626
Primary Topic
Medical Imaging and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Nondestructive automatic detection of bregma and lambda points in rodent skull anatomy images

Chunzhi Yi, Mengqiang Fu, Yuan Jun
Medical Imaging and Analysis
article

Nondestructive automatic detection of bregma and lambda points in rodent skull anatomy images

Chunzhi Yi, Mengqiang Fu, Yuan Jun
article en

Abstract

Based on an open-source image set, this study calculated the relative positional relationships between the eyes and the bregma and lambda points, using the nose tip as a reference point. We found that the correlation coefficients were as high as 0.942 and 0.935, respectively. Leveraging these findings, we fitted linear regression equations that can estimate the locations of the bregma and lambda points based on eye positions, with theoretical errors of 0.35mm and 0.57mm, respectively. Additionally, an automatic recognition algorithm for the nose tip and eyes was designed using openCV and YOLOV5, enabling automatic localization of the bregma and lambda points. Upon validation, the actual recognition errors of this method were 0.41mm and 0.66mm, respectively, demonstrating high precision. This noninvasive and straightforward automatic recognition approach not only effectively reduces surgical trauma to animals but also avoids the precision errors associated with manual positioning, offering new possibilities for the clinical application of brain-computer interface technology.

Harbin Institute of Technology (CN), Henan Academy of Sciences (CN)
Gender equality
Openalex Percentile: Top 88%
Medical Imaging and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.