The performance study of an odor gas monitor

Odor pollution has become a global environmental issue of increasing concern in recent years, and the odor gas monitor is widely used to measure the odor concentration, however, whether its value is still accurate and reliable after long-term use is unknown. In this work, the electrochemical odor monitor was chose and its performance and uncertainty were estimated. The result showed that the maximum absolute value of indication error of 8 standard gases was 9.17%, and other performance indicators such as zero shift, scale shift, response time and repeatability of the odor monitor were not more than 1.30%, 1.25%, 91s and 0.70% respectively. Moreover, when the concentrations of CH4S was 16.00 μmol/mol, the uncertainty was 0.34 μmol/mol. In a summary, the performance indicators and uncertainty of the monitor were excellent, and it need to keep the good status by means of calibrating periodically, and that could play an important role in preventing odor pollution.

Authors

Institutions

Publication Details

Published
2024-08-16
DOI
https://doi.org/10.1117/12.3035487
Citations
2
Primary Topic
Advanced Chemical Sensor Technologies
Type
article
Field-Weighted Citation Impact
0.37
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The performance study of an odor gas monitor

Y. Chen, Junchen Zou, Xiaoquan Sun, Xinyuan Cui et al.
2 citations
Advanced Chemical Sensor Technologies
0.37
article

The performance study of an odor gas monitor

Y. Chen, Junchen Zou, Xiaoquan Sun, Xinyuan Cui, Zhifeng He, Yuan Mu, Yang Ling, Dan Yuan, Yanzhao Wang
article en
2 citations

Abstract

Odor pollution has become a global environmental issue of increasing concern in recent years, and the odor gas monitor is widely used to measure the odor concentration, however, whether its value is still accurate and reliable after long-term use is unknown. In this work, the electrochemical odor monitor was chose and its performance and uncertainty were estimated. The result showed that the maximum absolute value of indication error of 8 standard gases was 9.17%, and other performance indicators such as zero shift, scale shift, response time and repeatability of the odor monitor were not more than 1.30%, 1.25%, 91s and 0.70% respectively. Moreover, when the concentrations of CH4S was 16.00 μmol/mol, the uncertainty was 0.34 μmol/mol. In a summary, the performance indicators and uncertainty of the monitor were excellent, and it need to keep the good status by means of calibrating periodically, and that could play an important role in preventing odor pollution.

Shandong Institute of Metrology (CN)
Affordable and clean energy
Openalex Percentile: Top 44%
Advanced Chemical Sensor Technologies
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

The performance study of an odor gas monitor — Y. Chen, Junchen Zou, et al. · (2024) | TGRS Research Map | TGRS