A Feasibility Study of a Respiratory Rate Measurement System Using Wearable MOx Sensors

Accurately obtaining a patient’s respiratory rate is crucial for promptly identifying any sudden changes in their condition during emergencies. Typically, the respiratory rate is assessed through a combination of impedance change measurements and electrocardiography (ECG). However, impedance measurements are prone to interference from body movements. Conversely, a capnometer coupled with a ventilator offers a method of measuring the respiratory rate that is unaffected by body movements. However, capnometers are mainly used to evaluate respiration when using a ventilator or an Ambu bag by measuring the CO2 concentration at the breathing circuit, and they are not used only to measure the respiratory rate. Furthermore, capnometers are not suitable as wearable devices because they require intubation or a mask that covers the nose and mouth to prevent air leaks during the measurement. In this study, we developed a reliable system for measuring the respiratory rate utilizing a small wearable MOx sensor that is unaffected by body movements and not connected to the breathing circuit. Subsequently, we conducted experimental assessments to gauge the accuracy of the rate estimation achieved by the system. In order to avoid the effects of abnormal states on the estimation accuracy, we also evaluated the classification performance for distinguishing between normal and abnormal respiration using a one-class SVM-based approach. The developed system achieved 80% for both true positive and true negative rates. Our experimental findings reveal that the respiratory rate can be precisely determined without being influenced by body movements.

Authors

Institutions

Publication Details

Journal
Information
Published
2024-08-16
DOI
https://doi.org/10.3390/info15080492
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Feasibility Study of a Respiratory Rate Measurement System Using Wearable MOx Sensors

R Omoto, Takunori Shimazaki, Takumi Kobayashi, Daisuke Anzai et al.
Information
Non-Invasive Vital Sign Monitoring
article

A Feasibility Study of a Respiratory Rate Measurement System Using Wearable MOx Sensors

R Omoto, Takunori Shimazaki, Takumi Kobayashi, Daisuke Anzai, Jaakko Hyry, M. Fukuda
article en

Abstract

Accurately obtaining a patient’s respiratory rate is crucial for promptly identifying any sudden changes in their condition during emergencies. Typically, the respiratory rate is assessed through a combination of impedance change measurements and electrocardiography (ECG). However, impedance measurements are prone to interference from body movements. Conversely, a capnometer coupled with a ventilator offers a method of measuring the respiratory rate that is unaffected by body movements. However, capnometers are mainly used to evaluate respiration when using a ventilator or an Ambu bag by measuring the CO2 concentration at the breathing circuit, and they are not used only to measure the respiratory rate. Furthermore, capnometers are not suitable as wearable devices because they require intubation or a mask that covers the nose and mouth to prevent air leaks during the measurement. In this study, we developed a reliable system for measuring the respiratory rate utilizing a small wearable MOx sensor that is unaffected by body movements and not connected to the breathing circuit. Subsequently, we conducted experimental assessments to gauge the accuracy of the rate estimation achieved by the system. In order to avoid the effects of abnormal states on the estimation accuracy, we also evaluated the classification performance for distinguishing between normal and abnormal respiration using a one-class SVM-based approach. The developed system achieved 80% for both true positive and true negative rates. Our experimental findings reveal that the respiratory rate can be precisely determined without being influenced by body movements.

InformationVol. 15(8)
Nagoya Institute of Technology (JP), Graduate School of Health Care Sciences, Jikei Institute (JP)
Jikei University School of Medicine, Japan Society for the Promotion of Science
Openalex Percentile: Top 88%
Non-Invasive Vital Sign Monitoring
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.