Pretreatment for potable reuse: Enhancing the biological removal of 1,4‐dioxane from landfill leachate through cometabolism with tetrahydrofuran

1,4-Dioxane is a probable human carcinogen and a persistent aquatic contaminant. Cometabolic biodegradation of 1,4-dioxane is a promising low-cost and effective treatment technology; however, further demonstration is needed for treating landfill leachate. This technology was tested in two full-scale moving bed biofilm reactors (MBBRs) treating raw landfill leachate with tetrahydrofuran selected as the cometabolite. The raw leachate contained on average 82 μg/L of 1,4-dioxane and before testing the MBBRs removed an average of 38% and 42% of 1,4-dioxane, respectively. First, tetrahydrofuran was added to MBBR 1, and 1,4-dioxane removal was improved to an average of 73%, with the control MBBR removing an average of 37% of 1,4-dioxane. During this period, an optimal dose of 2 mg/L of tetrahydrofuran was identified. Tetrahydrofuran was then fed to both MBBRs, where the 1,4-dioxane removal was on average 73% and 80%. Cometabolic treatment at the landfill significantly reduced the concentration of 1,4-dioxane received from the landfill at a downstream wastewater treatment and indirect potable reuse facility, reducing the load of 1,4-dioxane from 44% to 24% after the study. PRACTITIONER POINTS: Cometabolic degradation of leachate 1,4-dioxane with THF in MBBRs is a feasible treatment technology and a low-cost technique when retrofitting existing biological treatment facilities. The MBBRs can be operated at a range of temperatures, require no operational changes beyond THF addition, and operate best at a mass ratio of THF to 1,4-dioxane of 24. Source control of 1,4-dioxane significantly reduces the concentration of 1,4-dioxane in downstream wastewater treatment plants and potable reuse facilities.

Authors

Institutions

Publication Details

Journal
Water Environment Research
Published
2024-08-01
DOI
https://doi.org/10.1002/wer.11108
Citations
2
Primary Topic
Microbial bioremediation and biosurfactants
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pretreatment for potable reuse: Enhancing the biological removal of 1,4‐dioxane from landfill leachate through cometabolism with tetrahydrofuran

Rohan Menon, Charles B. Bott, Brian Brazil, Hannah Stohr et al.
2 citations
Water Environment Research
Microbial bioremediation and biosurfactants
0.27
article

Pretreatment for potable reuse: Enhancing the biological removal of 1,4‐dioxane from landfill leachate through cometabolism with tetrahydrofuran

Rohan Menon, Charles B. Bott, Brian Brazil, Hannah Stohr, Mike Martin, Micaela Griffin, James Sabo
article en
2 citations

Abstract

1,4-Dioxane is a probable human carcinogen and a persistent aquatic contaminant. Cometabolic biodegradation of 1,4-dioxane is a promising low-cost and effective treatment technology; however, further demonstration is needed for treating landfill leachate. This technology was tested in two full-scale moving bed biofilm reactors (MBBRs) treating raw landfill leachate with tetrahydrofuran selected as the cometabolite. The raw leachate contained on average 82 μg/L of 1,4-dioxane and before testing the MBBRs removed an average of 38% and 42% of 1,4-dioxane, respectively. First, tetrahydrofuran was added to MBBR 1, and 1,4-dioxane removal was improved to an average of 73%, with the control MBBR removing an average of 37% of 1,4-dioxane. During this period, an optimal dose of 2 mg/L of tetrahydrofuran was identified. Tetrahydrofuran was then fed to both MBBRs, where the 1,4-dioxane removal was on average 73% and 80%. Cometabolic treatment at the landfill significantly reduced the concentration of 1,4-dioxane received from the landfill at a downstream wastewater treatment and indirect potable reuse facility, reducing the load of 1,4-dioxane from 44% to 24% after the study. PRACTITIONER POINTS: Cometabolic degradation of leachate 1,4-dioxane with THF in MBBRs is a feasible treatment technology and a low-cost technique when retrofitting existing biological treatment facilities. The MBBRs can be operated at a range of temperatures, require no operational changes beyond THF addition, and operate best at a mass ratio of THF to 1,4-dioxane of 24. Source control of 1,4-dioxane significantly reduces the concentration of 1,4-dioxane in downstream wastewater treatment plants and potable reuse facilities.

Water Environment ResearchVol. 96(8)
Hampton Roads Sanitation District (US), Virginia Tech (US)
Clean water and sanitation
Openalex Percentile: Top 54%
Microbial bioremediation and biosurfactants
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.