Polyaniline/Poly(vinyl alcohol) Conductive Hydrogel for a Chemiresistive Ultrasensitive Ammonia Gas Sensor

Printing technology is an emerging microfabrication technique that is being explored as a potential alternative to traditional semiconductor technology. This innovative approach allows for high precision, ease of fabrication, integration of multiple incompatible materials, and scalability, leading to the production of low-cost and high-performance devices. Herein, we present the fabrication and investigation of a chemiresistive sensor utilizing micro girder (μG) printing technology employing a repetitive freeze–thaw (FT)-cycled polyaniline/poly(vinyl alcohol) (PANI/PVA) hydrogel as the sensing material for the detection of ammonia (NH3) gas down to 100 ppm at room temperature. The sensor shows an improved sensitivity of 94.7% for detecting 100 ppm of NH3 with a limit of detection of 1 ppm. The repetitive FT cycles promote the formation of well-defined microstructures of the hydrogels, which has been shown by detailed structural and morphological analyses. This hydrogel-based chemiresistive sensor demonstrated a good response to NH3 gas by monitoring changes in resistance, offering a cost-effective and practical alternative for NH3 detection. The sensor exhibited high sensitivity to NH3 with rapid response and recovery times of 25 and 10 s, respectively, making it suitable for real-time applications. Additionally, the study explored the hydrogel sensor’s cross-sensitivity to NH3, nitrogen dioxide (NO2), and carbon dioxide (CO2). The sensitivity of the sensor toward some of the breath volatile organic compounds is also analyzed. The sensor’s behavior is found to adhere to the Langmuir adsorption/desorption model, further confirming its efficacy in gas detection. The excellent sensing ability with a high cross-sensitivity of the developed sensor is attributed to the formation of well-developed cross-linked network structures during FT cycles. The stability of hydrogel-based sensors over a 3-month period further supports their potential for practical deployment in various environmental and healthcare monitoring scenarios, aiming to provide a straightforward strategy for detecting exhaled breath ammonia.

Authors

Institutions

Publication Details

Journal
ACS Applied Polymer Materials
Published
2024-08-15
DOI
https://doi.org/10.1021/acsapm.4c01766
Citations
17
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
3.14

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Polyaniline/Poly(vinyl alcohol) Conductive Hydrogel for a Chemiresistive Ultrasensitive Ammonia Gas Sensor

Roy P. Paily, Ashok Kumar Dasmahapatra, Leimapokpam Sophia Devi, Thomas T. Daniel
17 citations
ACS Applied Polymer Materials
Advanced Sensor and Energy Harvesting Materials
3.14
article

Polyaniline/Poly(vinyl alcohol) Conductive Hydrogel for a Chemiresistive Ultrasensitive Ammonia Gas Sensor

Roy P. Paily, Ashok Kumar Dasmahapatra, Leimapokpam Sophia Devi, Thomas T. Daniel
article en
17 citations

Abstract

Printing technology is an emerging microfabrication technique that is being explored as a potential alternative to traditional semiconductor technology. This innovative approach allows for high precision, ease of fabrication, integration of multiple incompatible materials, and scalability, leading to the production of low-cost and high-performance devices. Herein, we present the fabrication and investigation of a chemiresistive sensor utilizing micro girder (μG) printing technology employing a repetitive freeze–thaw (FT)-cycled polyaniline/poly(vinyl alcohol) (PANI/PVA) hydrogel as the sensing material for the detection of ammonia (NH3) gas down to 100 ppm at room temperature. The sensor shows an improved sensitivity of 94.7% for detecting 100 ppm of NH3 with a limit of detection of 1 ppm. The repetitive FT cycles promote the formation of well-defined microstructures of the hydrogels, which has been shown by detailed structural and morphological analyses. This hydrogel-based chemiresistive sensor demonstrated a good response to NH3 gas by monitoring changes in resistance, offering a cost-effective and practical alternative for NH3 detection. The sensor exhibited high sensitivity to NH3 with rapid response and recovery times of 25 and 10 s, respectively, making it suitable for real-time applications. Additionally, the study explored the hydrogel sensor’s cross-sensitivity to NH3, nitrogen dioxide (NO2), and carbon dioxide (CO2). The sensitivity of the sensor toward some of the breath volatile organic compounds is also analyzed. The sensor’s behavior is found to adhere to the Langmuir adsorption/desorption model, further confirming its efficacy in gas detection. The excellent sensing ability with a high cross-sensitivity of the developed sensor is attributed to the formation of well-developed cross-linked network structures during FT cycles. The stability of hydrogel-based sensors over a 3-month period further supports their potential for practical deployment in various environmental and healthcare monitoring scenarios, aiming to provide a straightforward strategy for detecting exhaled breath ammonia.

ACS Applied Polymer MaterialsVol. 6(17)
Indian Institute of Technology Guwahati (IN)
Ministry of Electronics and Information technology, Science and Engineering Research Board
Openalex Percentile: Top 8%
Advanced Sensor and Energy Harvesting Materials
3.14
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.