A feasibility study on the use of glycerol as a solution to waste renewable energy storage in the United Kingdom

• Reactor Efficiency: Achieves 94% glycerol conversion; three reactors per home handle peak loads by adjusting temperature. • Economic Impact: Operating costs are $76.5 per hour, with a capital cost of $33,000 per home, 60% of which is due to the catalyst. • Environmental Viability: Significantly reduces carbon emissions, but other pollutants need mitigation for better sustainability. This study has analysed to feasibility of incorporating a biologically derived liquid organic hydrogen carrier (LOHC) into the energy grid as a method of reducing waste renewable energy. With this goal in mind, a scenario has been devised in using glycerol to transport hydrogen for release at domestic homes for use in PEM fuel cells. Through this, a packed bed reactor can fulfil the average load with a glycerol conversion of 94 %. The peak load can be fulfilled by using 3 of these reactors at each home and reducing the temperature to decrease conversion when the energy is not needed. Through the dehydrogenation, many side products are formed, including methanol and ethanol which can be used to regenerate glycerol in a transesterification reaction. For a target conversion of 98 %, a 7.08 m 3 reactor vessel would be required to handle the alcohol output of 100 houses. After these simulations, an economic analysis and life cycle assessment was performed. The economic showed operating costs to be around 76.5 $/h, and the capital cost per home to be $33,000. 60% of this investment is the cost of the catalyst used in the dehydrogenation of glycerol. An alternative catalyst is required to reduce this total cost. The life cycle assessment showed very high effectiveness in reducing carbon missions, however, the other pollutants severely damper its viability.

Authors

Institutions

Publication Details

Journal
Energy Conversion and Management
Published
2024-08-15
DOI
https://doi.org/10.1016/j.enconman.2024.118873
Citations
1
Primary Topic
Hybrid Renewable Energy Systems
Type
article
Field-Weighted Citation Impact
0.17
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A feasibility study on the use of glycerol as a solution to waste renewable energy storage in the United Kingdom

Giuseppe Bagnato, Andy Lin
1 citations
Energy Conversion and Management
Hybrid Renewable Energy Systems
0.17
article

A feasibility study on the use of glycerol as a solution to waste renewable energy storage in the United Kingdom

Giuseppe Bagnato, Andy Lin
article en
1 citations

Abstract

• Reactor Efficiency: Achieves 94% glycerol conversion; three reactors per home handle peak loads by adjusting temperature. • Economic Impact: Operating costs are $76.5 per hour, with a capital cost of $33,000 per home, 60% of which is due to the catalyst. • Environmental Viability: Significantly reduces carbon emissions, but other pollutants need mitigation for better sustainability. This study has analysed to feasibility of incorporating a biologically derived liquid organic hydrogen carrier (LOHC) into the energy grid as a method of reducing waste renewable energy. With this goal in mind, a scenario has been devised in using glycerol to transport hydrogen for release at domestic homes for use in PEM fuel cells. Through this, a packed bed reactor can fulfil the average load with a glycerol conversion of 94 %. The peak load can be fulfilled by using 3 of these reactors at each home and reducing the temperature to decrease conversion when the energy is not needed. Through the dehydrogenation, many side products are formed, including methanol and ethanol which can be used to regenerate glycerol in a transesterification reaction. For a target conversion of 98 %, a 7.08 m 3 reactor vessel would be required to handle the alcohol output of 100 houses. After these simulations, an economic analysis and life cycle assessment was performed. The economic showed operating costs to be around 76.5 $/h, and the capital cost per home to be $33,000. 60% of this investment is the cost of the catalyst used in the dehydrogenation of glycerol. An alternative catalyst is required to reduce this total cost. The life cycle assessment showed very high effectiveness in reducing carbon missions, however, the other pollutants severely damper its viability.

Energy Conversion and ManagementVol. 319
Lancaster University (GB)
Affordable and clean energy
Openalex Percentile: Top 47%
Hybrid Renewable Energy Systems
0.17
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A feasibility study on the use of glycerol as a solution to waste renewable energy storage in the United Kingdom — Giuseppe Bagnato, Andy Lin · Energy Conversion and Management (2024) | TGRS Research Map | TGRS