Corrosion studies of Inconel 617 in high temperature air and He-ppmO2 atmospheres

Air ingress accident is one of the typical accident conditions in Very High Temperature Reactors (VHTRs). This work investigates the oxidation kinetics, corrosion behavior and mechanism of Inconel 617 alloy in different oxygen concentration atmospheres under air ingress accident. The impact of O 2 concentration and oxidation time of the alloy corrosion is investigated. A gas chromatograph was used to measure the impurity content in real time during the helium experiments. After the experiments, the alloys were characterized by electronic balance, were analyzed by Scanning Electron Microscopy (SEM), Energy-Dispersive X-ray Spectroscopy (EDS), X-ray diffraction (XRD) and carbon and sulfur analyzer. The results show that: the Inconel 617 alloy undergoes similar oxidation behavior and the degree of oxidation is very close in three groups of atmospheres with large differences in oxygen content; the alloy should show two oxidation mechanisms, linear oxidation and parabolic oxidation, during the oxidation process; the parabolic rate constant k p and k t of the alloy is a constant value and does not vary with large changes in oxygen concentration, but when the experimental temperature changes, the oxidation rate constants of the alloy change, and the lowering of the temperature leads to the lowering of the oxidation rate constants; When experimental temperature is at 950 °C, the alloy continues to undergo a “microclimatic reaction” in the atmosphere of He-ppmO 2 , and the microclimatic reaction disappears when the experimental temperature is lowered to 750 °C; In He-ppmO 2 environment, gas chromatograph can be used instead of thermogravimetric analyzer for real-time monitoring.

Authors

Institutions

Publication Details

Journal
Nuclear Engineering and Technology
Published
2024-08-15
DOI
https://doi.org/10.1016/j.net.2024.08.023
Citations
3
Primary Topic
Graphite, nuclear technology, radiation studies
Type
article
Field-Weighted Citation Impact
0.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Corrosion studies of Inconel 617 in high temperature air and He-ppmO2 atmospheres

Huang Zhang, Tao Ma, Huaqiang Yin, Xingtuan Yang et al.
3 citations
Nuclear Engineering and Technology
Graphite, nuclear technology, radiation studies
0.35
article

Corrosion studies of Inconel 617 in high temperature air and He-ppmO2 atmospheres

Huang Zhang, Tao Ma, Huaqiang Yin, Xingtuan Yang, Bin Du, Xuedong He, Wei Zheng
article en
3 citations

Abstract

Air ingress accident is one of the typical accident conditions in Very High Temperature Reactors (VHTRs). This work investigates the oxidation kinetics, corrosion behavior and mechanism of Inconel 617 alloy in different oxygen concentration atmospheres under air ingress accident. The impact of O 2 concentration and oxidation time of the alloy corrosion is investigated. A gas chromatograph was used to measure the impurity content in real time during the helium experiments. After the experiments, the alloys were characterized by electronic balance, were analyzed by Scanning Electron Microscopy (SEM), Energy-Dispersive X-ray Spectroscopy (EDS), X-ray diffraction (XRD) and carbon and sulfur analyzer. The results show that: the Inconel 617 alloy undergoes similar oxidation behavior and the degree of oxidation is very close in three groups of atmospheres with large differences in oxygen content; the alloy should show two oxidation mechanisms, linear oxidation and parabolic oxidation, during the oxidation process; the parabolic rate constant k p and k t of the alloy is a constant value and does not vary with large changes in oxygen concentration, but when the experimental temperature changes, the oxidation rate constants of the alloy change, and the lowering of the temperature leads to the lowering of the oxidation rate constants; When experimental temperature is at 950 °C, the alloy continues to undergo a “microclimatic reaction” in the atmosphere of He-ppmO 2 , and the microclimatic reaction disappears when the experimental temperature is lowered to 750 °C; In He-ppmO 2 environment, gas chromatograph can be used instead of thermogravimetric analyzer for real-time monitoring.

Nuclear Engineering and TechnologyVol. 57(1)
Key Laboratory of Nuclear Radiation and Nuclear Energy Technology (CN), Tsinghua University (CN)
Openalex Percentile: Top 45%
Graphite, nuclear technology, radiation studies
0.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.