Assessment of retinal blood vessel segmentation using U-Net model: A deep learning approach

Segmentation of retinal blood vessels from fundus images is vital to assist ophthalmologists in diagnosing different eye diseases like Arteriosclerosis, Glaucoma, Diabetic Retinopathy, Hypertension, and Choroidal Neovascularization. Accurate detection and timely treatment of these eye diseases can prevent irreversible impairment of vision. In computer-aided automatic diagnosis, Preprocessing of fundus images is necessary to reduce the uneven retinal image illumination, as well as the undesirable effect arising from the contrast differences between the retinal blood vessels and the background. In this study, the Hessian-based Frangi vesselness filter is proposed to enhance vasculature in fundus images. This approach seeks to extract thin vessels to diminish the intensity disparity between thick and thin vessels. Its accuracy has never, however, been thoroughly evaluated. To verify the effectiveness of the suggested filter for boosting vessel-like structures in the fundus images, an experimental approach is presented in this paper. The ability of the filter to improve vessel-like structures in fundus images is validated, and an experimental technique for evaluating filter performance using the U-Net model is described. Five quantitative performances, namely Accuracy, Recall, Specificity, Precision, and F1 Score measures on the DRIVE, HRF, DIARETDB1, DIARETDB0, CHASEDB1, ORIGA, DRISHTI GS, DRIONS DB, FIRE, and FIOT datasets, were evaluated and quantified in these experiments to validate the efficacy of the proposed filter. The results demonstrated a noteworthy improvement by achieving an Accuracy of 99.79 %, 99.84 %, 99.64 %, 99.72 %, 99.57 %, 99.48 %, 99.77 %, 99.05 %, 99.93 %, and 99.40 % respectively. Empirical evidence supports the advantages of this approach.

Authors

Institutions

Publication Details

Journal
Franklin Open
Published
2024-08-15
DOI
https://doi.org/10.1016/j.fraope.2024.100143
Citations
8
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
3.23
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of retinal blood vessel segmentation using U-Net model: A deep learning approach

Madhusudhan Mishra, Smita Das, Swanirbhar Majumder, Suvadip Chakraborty
8 citations
Franklin Open
Retinal Imaging and Analysis
3.23
article

Assessment of retinal blood vessel segmentation using U-Net model: A deep learning approach

Madhusudhan Mishra, Smita Das, Swanirbhar Majumder, Suvadip Chakraborty
article en
8 citations

Abstract

Segmentation of retinal blood vessels from fundus images is vital to assist ophthalmologists in diagnosing different eye diseases like Arteriosclerosis, Glaucoma, Diabetic Retinopathy, Hypertension, and Choroidal Neovascularization. Accurate detection and timely treatment of these eye diseases can prevent irreversible impairment of vision. In computer-aided automatic diagnosis, Preprocessing of fundus images is necessary to reduce the uneven retinal image illumination, as well as the undesirable effect arising from the contrast differences between the retinal blood vessels and the background. In this study, the Hessian-based Frangi vesselness filter is proposed to enhance vasculature in fundus images. This approach seeks to extract thin vessels to diminish the intensity disparity between thick and thin vessels. Its accuracy has never, however, been thoroughly evaluated. To verify the effectiveness of the suggested filter for boosting vessel-like structures in the fundus images, an experimental approach is presented in this paper. The ability of the filter to improve vessel-like structures in fundus images is validated, and an experimental technique for evaluating filter performance using the U-Net model is described. Five quantitative performances, namely Accuracy, Recall, Specificity, Precision, and F1 Score measures on the DRIVE, HRF, DIARETDB1, DIARETDB0, CHASEDB1, ORIGA, DRISHTI GS, DRIONS DB, FIRE, and FIOT datasets, were evaluated and quantified in these experiments to validate the efficacy of the proposed filter. The results demonstrated a noteworthy improvement by achieving an Accuracy of 99.79 %, 99.84 %, 99.64 %, 99.72 %, 99.57 %, 99.48 %, 99.77 %, 99.05 %, 99.93 %, and 99.40 % respectively. Empirical evidence supports the advantages of this approach.

Franklin OpenVol. 8
North Eastern Regional Institute of Science and Technology (IN), Tripura University (IN)
Openalex Percentile: Top 8%
Retinal Imaging and Analysis
3.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.