Experimental investigation of humidified air condensation in different rows of serpantine heat exchanger – Cooling water flow rate effect

Condensing economizers are used in the industry as they enable the acquisition of additional heat during vapor condensation. In condensing heat exchangers, water is the usual cooling agent due to its high specific heat capacity and thus efficient heat removal. Therefore, experiments of hot humid air condensation in a serpentine economizer being cooled by water were performed to reveal the effect the cooling water flow rate has on humidified air condensation in separate rows of the serpentine type economizer (with vertical tubes). The results have shown that the cooling ratio (mass flow ratio between the coolant and the humid air) had a minor effect on the distribution of the humidified air temperature along test section for inlet Reynolds number of 3000–10000. The effects on the condensation flux distribution in different rows were much stronger. The most optimal cooling ratio was determined to be 3. The results have shown that the biggest condensation efficiency is up to 35 %. It was revealed that in some cases the convection was prevailing in the first rows of the economizer and this resulted in a decreased efficiency/performance of the exchanger. The obtained results from the practical point of view will provide an extended basis for the optimisation of the design of economizers for waste heat recovery in the cases of different cooling water flow rates. It could also be applied to validate computational models developed for condensation heat transfer and condensate flux numerical modelling along economizer.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2024-08-15
DOI
https://doi.org/10.1016/j.tsep.2024.102814
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental investigation of humidified air condensation in different rows of serpantine heat exchanger – Cooling water flow rate effect

Povilas Poškas, Arūnas Sirvydas, Robertas Poškas, Hussam Jouhara et al.
Thermal Science and Engineering Progress
Heat Transfer and Optimization
article

Experimental investigation of humidified air condensation in different rows of serpantine heat exchanger – Cooling water flow rate effect

Povilas Poškas, Arūnas Sirvydas, Robertas Poškas, Hussam Jouhara, M. Salem
article en

Abstract

Condensing economizers are used in the industry as they enable the acquisition of additional heat during vapor condensation. In condensing heat exchangers, water is the usual cooling agent due to its high specific heat capacity and thus efficient heat removal. Therefore, experiments of hot humid air condensation in a serpentine economizer being cooled by water were performed to reveal the effect the cooling water flow rate has on humidified air condensation in separate rows of the serpentine type economizer (with vertical tubes). The results have shown that the cooling ratio (mass flow ratio between the coolant and the humid air) had a minor effect on the distribution of the humidified air temperature along test section for inlet Reynolds number of 3000–10000. The effects on the condensation flux distribution in different rows were much stronger. The most optimal cooling ratio was determined to be 3. The results have shown that the biggest condensation efficiency is up to 35 %. It was revealed that in some cases the convection was prevailing in the first rows of the economizer and this resulted in a decreased efficiency/performance of the exchanger. The obtained results from the practical point of view will provide an extended basis for the optimisation of the design of economizers for waste heat recovery in the cases of different cooling water flow rates. It could also be applied to validate computational models developed for condensation heat transfer and condensate flux numerical modelling along economizer.

Thermal Science and Engineering ProgressVol. 54
Lithuanian Energy Institute (LT), Brunel University of London (GB)
HORIZON EUROPE Framework Programme, H2020 European Research Council
Clean water and sanitation
Openalex Percentile: Top 87%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.