Enhancing Precision in Radiation Therapy for Locally Advanced Lung Cancer: A Case Study of Cone-Beam Computed Tomography (CBCT)-Based Online Adaptive Techniques and the Promise of HyperSight™ Iterative CBCT

This study explores the dosimetric benefits of cone-beam computed tomography (CBCT)-based online adaptive radiation therapy (oART) for a non-small-cell lung cancer (NSCLC) patient exhibiting significant tumor shrinkage during ChemoRT. The patient was prescribed 60 Gray (Gy) in 30 fractions and was initially treated with conventional RT. After the delivery of the first four treatment fractions, the patient's treatment course was converted to oART due to tumor shrinkage seen on CBCT. Current oART dose calculations use a synthetic CT (sCT) image derived from deformable image registration (DIR) of the planning CT to the daily CBCT, and, as the tumor regressed, the discrepancy between the CBCT and the sCT increased, leading to a re-simulation after the delivery of the ninth fraction. In this case report, we first investigated dosimetric differences leveraged by converting this patient from conventional RT to oART. With oART using sCT, the patient's target coverage remained consistent with the reference plan while simultaneously changing lung V20 by 7.8 ± 1.4% and heart mean by 3.4 ± 1.5 Gy. Then, using this new simulation CT and comparing it with iterative CBCT (iCBCT) images acquired with the new HyperSight™ (HS) (Varian Medical Systems, Inc., Palo Alto, CA, USA) imaging system on the Ethos, we investigated the impact of direct dose calculation on HS-iCBCT as compared to sCT. The HS-iCBCT generated a dose distribution similar to the CT reference, achieving a 96.01% gamma passing rate using Task Group-218 (TG-218) criteria. Results indicate that HS-iCBCT has the potential to better reflect daily anatomical changes, resulting in improved dosimetric accuracy. This study highlights the advantages of oART in the presence of tumor response to therapy and underscores HS-iCBCT's potential to provide CT-level dose calculation accuracy in oART for NSCLC patients.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2024-08-15
DOI
https://doi.org/10.7759/cureus.66943
Citations
7
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
4.25
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Enhancing Precision in Radiation Therapy for Locally Advanced Lung Cancer: A Case Study of Cone-Beam Computed Tomography (CBCT)-Based Online Adaptive Techniques and the Promise of HyperSight™ Iterative CBCT

Joel A. Pogue, Joseph Harms, Jingwei Duan, Drexell H. Boggs
7 citations
Cureus
Advanced Radiotherapy Techniques
4.25
article

Enhancing Precision in Radiation Therapy for Locally Advanced Lung Cancer: A Case Study of Cone-Beam Computed Tomography (CBCT)-Based Online Adaptive Techniques and the Promise of HyperSight™ Iterative CBCT

Joel A. Pogue, Joseph Harms, Jingwei Duan, Drexell H. Boggs
article en
7 citations

Abstract

This study explores the dosimetric benefits of cone-beam computed tomography (CBCT)-based online adaptive radiation therapy (oART) for a non-small-cell lung cancer (NSCLC) patient exhibiting significant tumor shrinkage during ChemoRT. The patient was prescribed 60 Gray (Gy) in 30 fractions and was initially treated with conventional RT. After the delivery of the first four treatment fractions, the patient's treatment course was converted to oART due to tumor shrinkage seen on CBCT. Current oART dose calculations use a synthetic CT (sCT) image derived from deformable image registration (DIR) of the planning CT to the daily CBCT, and, as the tumor regressed, the discrepancy between the CBCT and the sCT increased, leading to a re-simulation after the delivery of the ninth fraction. In this case report, we first investigated dosimetric differences leveraged by converting this patient from conventional RT to oART. With oART using sCT, the patient's target coverage remained consistent with the reference plan while simultaneously changing lung V20 by 7.8 ± 1.4% and heart mean by 3.4 ± 1.5 Gy. Then, using this new simulation CT and comparing it with iterative CBCT (iCBCT) images acquired with the new HyperSight™ (HS) (Varian Medical Systems, Inc., Palo Alto, CA, USA) imaging system on the Ethos, we investigated the impact of direct dose calculation on HS-iCBCT as compared to sCT. The HS-iCBCT generated a dose distribution similar to the CT reference, achieving a 96.01% gamma passing rate using Task Group-218 (TG-218) criteria. Results indicate that HS-iCBCT has the potential to better reflect daily anatomical changes, resulting in improved dosimetric accuracy. This study highlights the advantages of oART in the presence of tumor response to therapy and underscores HS-iCBCT's potential to provide CT-level dose calculation accuracy in oART for NSCLC patients.

CureusVol. 16(8)
University of Alabama at Birmingham (US)
Good health and well-being
Openalex Percentile: Top 6%
Advanced Radiotherapy Techniques
4.25
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.