PRT Shaping Method for Heart Rate Variability Monitoring Using Phase- and Quadrature Self-Injection-Locked (PQSIL) Radar

This article proposes a PRT shaping algorithm, which is used in conjunction with a 2.4-GHz phase- and quadrature self-injection-locked (PQSIL) radar for noncontact heart rate variability (HRV) monitoring. To validate the demodulated signal measured from the radar system, experiments were conducted on actuators executing minute variable-frequency motions, which could be recovered without distortion. The PRT shaping algorithm for enhancing the heartbeat features and obtaining the HRV was processed in the time domain to avoid the tradeoff between the window length and frequency resolution typically encountered in frequency-domain analysis. Specifically, the breathing-related motion was first removed from the signal, and the heartbeat features were enhanced via autocorrelation. Subsequently, one-cycle segmentation was performed before using the PRT model to eliminate the initial peak deviation within a heartbeat cycle duration, based on the cardiac rhythm corresponding to the P, R, and T waves. The R peaks of the waveforms obtained after PRT shaping were compared with those of a reference electrocardiogram (ECG) signal. For experimental verification, noncontact HRV monitoring was performed for five subjects seated 1-m away from the radar. The feasibility of the proposed method was verified in terms of various evaluation indicators for HRV analysis, including an overall average mean relative error (MRE) of <2% and a 5 beats per minute (bpm) accuracy of 100%.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Microwave Theory and Techniques
Published
2024-08-15
DOI
https://doi.org/10.1109/tmtt.2024.3439522
Citations
4
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PRT Shaping Method for Heart Rate Variability Monitoring Using Phase- and Quadrature Self-Injection-Locked (PQSIL) Radar

Ju-Yin Shih, Ji-Xun Zhong, Yu-Jen Chu, Fu-Kang Wang
4 citations
IEEE Transactions on Microwave Theory and Techniques
Non-Invasive Vital Sign Monitoring
0.74
article

PRT Shaping Method for Heart Rate Variability Monitoring Using Phase- and Quadrature Self-Injection-Locked (PQSIL) Radar

Ju-Yin Shih, Ji-Xun Zhong, Yu-Jen Chu, Fu-Kang Wang
article en
4 citations

Abstract

This article proposes a PRT shaping algorithm, which is used in conjunction with a 2.4-GHz phase- and quadrature self-injection-locked (PQSIL) radar for noncontact heart rate variability (HRV) monitoring. To validate the demodulated signal measured from the radar system, experiments were conducted on actuators executing minute variable-frequency motions, which could be recovered without distortion. The PRT shaping algorithm for enhancing the heartbeat features and obtaining the HRV was processed in the time domain to avoid the tradeoff between the window length and frequency resolution typically encountered in frequency-domain analysis. Specifically, the breathing-related motion was first removed from the signal, and the heartbeat features were enhanced via autocorrelation. Subsequently, one-cycle segmentation was performed before using the PRT model to eliminate the initial peak deviation within a heartbeat cycle duration, based on the cardiac rhythm corresponding to the P, R, and T waves. The R peaks of the waveforms obtained after PRT shaping were compared with those of a reference electrocardiogram (ECG) signal. For experimental verification, noncontact HRV monitoring was performed for five subjects seated 1-m away from the radar. The feasibility of the proposed method was verified in terms of various evaluation indicators for HRV analysis, including an overall average mean relative error (MRE) of <2% and a 5 beats per minute (bpm) accuracy of 100%.

IEEE Transactions on Microwave Theory and TechniquesVol. 73(2)
National Sun Yat-sen University (TW)
National Science and Technology Council
Openalex Percentile: Top 33%
Non-Invasive Vital Sign Monitoring
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.