KOJI AWARENESS, a self-rating whole-body movement assessment system, has intersession reliability and comparability to external examiner rating

KOJI AWARENESS is a newly developed self-rating whole-body movement assessment system that includes 11 domains and 22 tests. The primary aim of this study was to investigate the intersession reliability of KOJI AWARENESS, and the secondary aim was to determine whether a fixed bias existed between self-rating and external examiner rating. Fifty university students rated their movement ability in two separate sessions; an external examiner also rated the students' movement ability. Participants were blinded to their scores at the first session as well as the external examiner's rating scores. The primary analysis included examining the intersession reliability of the total score with intraclass correlation coefficients (ICCs). ICC values were interpreted as follows: insufficient, < .7 and sufficient, ≥ .7. To achieve the secondary aim, Bland-Altman analysis was performed. ICC for the intersession reliability was .86 with a 95% confidence interval (CI) of .77 to .92 and a minimum detectable change (MDC) of 5.15. Bland-Altman analysis revealed fixed bias as the 95% CIs of the mean difference between the two different rating scores (-3.49 to -2.43 and -3.94 to -2.98 in the first and second sessions, respectively) did not include 0 in the data of each session. However, no proportional bias was identified because no statistically significant Pearson's correlation (P > .05) was noted between the means of the two methods and the mean difference between the two different methods in each session. This study identified that KOJI AWARENESS has sufficient intersession reliability among relatively young and healthy participants. External examiner rating tended to have lower total scores than self-rating; however, the bias was below the MDC and seemed not to be clinically significant.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2024-08-15
DOI
https://doi.org/10.1371/journal.pone.0308973
Citations
1
Primary Topic
Cerebral Palsy and Movement Disorders
Type
article
Field-Weighted Citation Impact
0.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

KOJI AWARENESS, a self-rating whole-body movement assessment system, has intersession reliability and comparability to external examiner rating

Hiroshi Takasaki, Shunsuke Kanayasu
1 citations
PLoS ONE
Cerebral Palsy and Movement Disorders
0.39
article

KOJI AWARENESS, a self-rating whole-body movement assessment system, has intersession reliability and comparability to external examiner rating

Hiroshi Takasaki, Shunsuke Kanayasu
article en
1 citations

Abstract

KOJI AWARENESS is a newly developed self-rating whole-body movement assessment system that includes 11 domains and 22 tests. The primary aim of this study was to investigate the intersession reliability of KOJI AWARENESS, and the secondary aim was to determine whether a fixed bias existed between self-rating and external examiner rating. Fifty university students rated their movement ability in two separate sessions; an external examiner also rated the students' movement ability. Participants were blinded to their scores at the first session as well as the external examiner's rating scores. The primary analysis included examining the intersession reliability of the total score with intraclass correlation coefficients (ICCs). ICC values were interpreted as follows: insufficient, < .7 and sufficient, ≥ .7. To achieve the secondary aim, Bland-Altman analysis was performed. ICC for the intersession reliability was .86 with a 95% confidence interval (CI) of .77 to .92 and a minimum detectable change (MDC) of 5.15. Bland-Altman analysis revealed fixed bias as the 95% CIs of the mean difference between the two different rating scores (-3.49 to -2.43 and -3.94 to -2.98 in the first and second sessions, respectively) did not include 0 in the data of each session. However, no proportional bias was identified because no statistically significant Pearson's correlation (P > .05) was noted between the means of the two methods and the mean difference between the two different methods in each session. This study identified that KOJI AWARENESS has sufficient intersession reliability among relatively young and healthy participants. External examiner rating tended to have lower total scores than self-rating; however, the bias was below the MDC and seemed not to be clinically significant.

PLoS ONEVol. 19(8)
Saitama Prefectural University (JP)
Quality Education
Openalex Percentile: Top 37%
Cerebral Palsy and Movement Disorders
0.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.