High-Efficiency Interdigitated Electrode-Based Droplet Merger for Enabling Error-Free Droplet Microfluidic Systems

Merging two droplets into a droplet to add and mix two contents is one of the common droplet microfluidic functions with droplet generation and sorting, performing broad ranges of biological and chemical assays in droplets. However, traditional droplet-merging techniques often encounter unsynchronized droplets, causing overmerging or mis-merging, and unwanted merging outside of the desired zone. This is more severe when the incoming droplets to be merged are polydisperse in their sizes, often observed in assays that require long-term incubation, elevated-temperature, and/or multiple droplet processing steps. Here, we developed an interdigitated electrode (IDE)-based droplet merger consisting of a droplet autosynchronizing channel and a merging channel. The autosynchronizing channel provides >95% merging efficiency even when 20% polydispersity in the droplet size exists. The highly localized and enhanced dielectrophoretic force generated by the IDEs on the channel bottom allows droplet merging at an extremely low voltage (4.5 V) and only locally at the IDE region. A systematic evaluation of how various design and operation parameters of the IDE merger, such as IDE finger dimensions, dielectric coating layer thickness, droplet size, and droplet flow speed impact the performance was conducted. The optimized device showed consistent performance even when operating for up to 100 h consecutively at high throughput (100 droplets/s). The presented technology has been integrated into a droplet microfluidics workflow to test the lytic activities of bacteriophage on bacterial host cells with 100% merging efficiency. We expect this function to be integrated into droplet microfluidic systems performing broad ranges of high-throughput chemical and biological assays.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2024-08-15
DOI
https://doi.org/10.1021/acs.analchem.4c02376
Citations
4
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
0.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

High-Efficiency Interdigitated Electrode-Based Droplet Merger for Enabling Error-Free Droplet Microfluidic Systems

Yuwen Li, Adrian R. Guzman, Can Huang, Arum Han et al.
4 citations
Analytical Chemistry
Innovative Microfluidic and Catalytic Techniques Innovation
0.74
article

High-Efficiency Interdigitated Electrode-Based Droplet Merger for Enabling Error-Free Droplet Microfluidic Systems

Yuwen Li, Adrian R. Guzman, Can Huang, Arum Han, Han Zhang, Jeong Jae Han
article en
4 citations

Abstract

Merging two droplets into a droplet to add and mix two contents is one of the common droplet microfluidic functions with droplet generation and sorting, performing broad ranges of biological and chemical assays in droplets. However, traditional droplet-merging techniques often encounter unsynchronized droplets, causing overmerging or mis-merging, and unwanted merging outside of the desired zone. This is more severe when the incoming droplets to be merged are polydisperse in their sizes, often observed in assays that require long-term incubation, elevated-temperature, and/or multiple droplet processing steps. Here, we developed an interdigitated electrode (IDE)-based droplet merger consisting of a droplet autosynchronizing channel and a merging channel. The autosynchronizing channel provides >95% merging efficiency even when 20% polydispersity in the droplet size exists. The highly localized and enhanced dielectrophoretic force generated by the IDEs on the channel bottom allows droplet merging at an extremely low voltage (4.5 V) and only locally at the IDE region. A systematic evaluation of how various design and operation parameters of the IDE merger, such as IDE finger dimensions, dielectric coating layer thickness, droplet size, and droplet flow speed impact the performance was conducted. The optimized device showed consistent performance even when operating for up to 100 h consecutively at high throughput (100 droplets/s). The presented technology has been integrated into a droplet microfluidics workflow to test the lytic activities of bacteriophage on bacterial host cells with 100% merging efficiency. We expect this function to be integrated into droplet microfluidic systems performing broad ranges of high-throughput chemical and biological assays.

Analytical Chemistry
Texas A&M University (US)
National Institute of Allergy and Infectious Diseases
Affordable and clean energy
Openalex Percentile: Top 33%
Innovative Microfluidic and Catalytic Techniques Innovation
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.