Noncontact Temperature Measurement of Metal Surfaces Using Reflected Laser Beam

A temperature measurement system with a reflected laser beam that does not require temperature modulation was developed for the thermal design of electronic devices.The system combines a balanced photodetector and lock-in amplifier to make reflectance change measurements possible with an extremely high signal-to-noise ratio.First, to evaluate the accuracy of the reflectance change measurement, the reflectance change of a Ni thin film temperature-controlled by a heater and thermocouples was measured as a function of temperature change.To evaluate the accuracy of the temperature change measurement, the reflectance change was measured by heating a Ni thin film that imitated the wiring pattern of an electronic circuit.The experimental results showed that the standard deviation of the ratio of reflectance change from the reference reflectance was <1.00 × 10 -5 at a constant temperature.Moreover, the error margin of the calculated temperature change was ±1.0% for a change of 22 °C or more from the reference temperature, and the performance was sufficient for the estimation of local temperature.

Authors

Institutions

Publication Details

Journal
Sensors and Materials
Published
2024-08-15
DOI
https://doi.org/10.18494/sam5165
Primary Topic
Advanced Sensor Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noncontact Temperature Measurement of Metal Surfaces Using Reflected Laser Beam

Taichi Murakami, Toshiyuki Tsuchiya, Masaki Shimofuri, Shugo Miyake
Sensors and Materials
Advanced Sensor Technologies Research
article

Noncontact Temperature Measurement of Metal Surfaces Using Reflected Laser Beam

Taichi Murakami, Toshiyuki Tsuchiya, Masaki Shimofuri, Shugo Miyake
article en

Abstract

A temperature measurement system with a reflected laser beam that does not require temperature modulation was developed for the thermal design of electronic devices.The system combines a balanced photodetector and lock-in amplifier to make reflectance change measurements possible with an extremely high signal-to-noise ratio.First, to evaluate the accuracy of the reflectance change measurement, the reflectance change of a Ni thin film temperature-controlled by a heater and thermocouples was measured as a function of temperature change.To evaluate the accuracy of the temperature change measurement, the reflectance change was measured by heating a Ni thin film that imitated the wiring pattern of an electronic circuit.The experimental results showed that the standard deviation of the ratio of reflectance change from the reference reflectance was <1.00 × 10 -5 at a constant temperature.Moreover, the error margin of the calculated temperature change was ±1.0% for a change of 22 °C or more from the reference temperature, and the performance was sufficient for the estimation of local temperature.

Sensors and MaterialsVol. 36(8)
Setsunan University (JP), Kyoto University (JP)
Affordable and clean energy
Openalex Percentile: Top 88%
Advanced Sensor Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Noncontact Temperature Measurement of Metal Surfaces Using Reflected Laser Beam — Taichi Murakami, Toshiyuki Tsuchiya, et al. · Sensors and Materials (2024) | TGRS Research Map | TGRS