A new approach to instantaneous power based control of DFIG using active disturbance rejection control

• DFIG's control strategy based on active and reactive power using linear ADRC regulator is presented. • Single parameter based and genetic algorithm based parameter tuning of L-ADRC is discussed. • Cases like load change and fault in different modes of operation of DFIG, wind speed variation are presented. • The L-ADRC's robustness is investigated by comparing results while varying machine's internal parameters. • Experimental validation of control strategy for load change under sub synchronous mode of operation is presented. This paper presents the design and control of a wind energy converter system that uses a doubly fed induction generator. It introduces a model that incorporates instantaneous active and reactive power as state variables to represent both the stator and rotor sides of the doubly fed induction generator. Subsequently, a linear active disturbance rejection-based control regulator is proposed for the control loops. The parameters of the linear active disturbance rejection controllers (ADRC) are adjusted by two methods: the single parameter tuning approach and the genetic algorithm (GA) method. The performance of the suggested controller is ultimately compared with a tuned proportional-integral (PI) control regulator in the MATLAB environment. In order to examine the performance of the system, various test scenarios are taken into account. These scenarios include different percentages of load change in both sub-synchronous and super-synchronous modes of operation, faults with different fault periods are considered in both modes of operation. The conventional PI controller-based approach requires 35 control cycles to reach steady state under load change conditions and 50 control cycles under symmetrical fault conditions, regardless of whether the system is operating in sub synchronous or super synchronous mode. The single parameter-based tuned ADRC approach only requires 15 control cycles for load change and 20 control cycles for symmetrical fault scenarios. In contrast, for both the load change and symmetrical fault scenarios, the ADRC with GA-based parameter tuning reaches steady state in just 5 control cycles. Furthermore, a case involving wind speed variation is presented to demonstrate the maximum power point tracking capability of the proposed control structure. Similarly, for the robustness test of the control regulator, variations in resistance and inductance are introduced to observe their impact on the response of the control regulators. Finally, a real-time hardware in loop setup is presented to validate the control strategy during the load change in the sub-synchronous mode of operation of the doubly fed induction generator.

Authors

Institutions

Publication Details

Journal
e-Prime - Advances in Electrical Engineering Electronics and Energy
Published
2024-08-15
DOI
https://doi.org/10.1016/j.prime.2024.100740
Citations
4
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.83
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A new approach to instantaneous power based control of DFIG using active disturbance rejection control

P.K. Dash, Shibani Prasad Mohapatra, Ranjeeta Bisoi
4 citations
e-Prime - Advances in Electrical Engineering Electronics and Energy
Wind Turbine Control Systems
0.83
article

A new approach to instantaneous power based control of DFIG using active disturbance rejection control

P.K. Dash, Shibani Prasad Mohapatra, Ranjeeta Bisoi
article en
4 citations

Abstract

• DFIG's control strategy based on active and reactive power using linear ADRC regulator is presented. • Single parameter based and genetic algorithm based parameter tuning of L-ADRC is discussed. • Cases like load change and fault in different modes of operation of DFIG, wind speed variation are presented. • The L-ADRC's robustness is investigated by comparing results while varying machine's internal parameters. • Experimental validation of control strategy for load change under sub synchronous mode of operation is presented. This paper presents the design and control of a wind energy converter system that uses a doubly fed induction generator. It introduces a model that incorporates instantaneous active and reactive power as state variables to represent both the stator and rotor sides of the doubly fed induction generator. Subsequently, a linear active disturbance rejection-based control regulator is proposed for the control loops. The parameters of the linear active disturbance rejection controllers (ADRC) are adjusted by two methods: the single parameter tuning approach and the genetic algorithm (GA) method. The performance of the suggested controller is ultimately compared with a tuned proportional-integral (PI) control regulator in the MATLAB environment. In order to examine the performance of the system, various test scenarios are taken into account. These scenarios include different percentages of load change in both sub-synchronous and super-synchronous modes of operation, faults with different fault periods are considered in both modes of operation. The conventional PI controller-based approach requires 35 control cycles to reach steady state under load change conditions and 50 control cycles under symmetrical fault conditions, regardless of whether the system is operating in sub synchronous or super synchronous mode. The single parameter-based tuned ADRC approach only requires 15 control cycles for load change and 20 control cycles for symmetrical fault scenarios. In contrast, for both the load change and symmetrical fault scenarios, the ADRC with GA-based parameter tuning reaches steady state in just 5 control cycles. Furthermore, a case involving wind speed variation is presented to demonstrate the maximum power point tracking capability of the proposed control structure. Similarly, for the robustness test of the control regulator, variations in resistance and inductance are introduced to observe their impact on the response of the control regulators. Finally, a real-time hardware in loop setup is presented to validate the control strategy during the load change in the sub-synchronous mode of operation of the doubly fed induction generator.

e-Prime - Advances in Electrical Engineering Electronics and EnergyVol. 9
Siksha O Anusandhan University (IN)
Climate action, Affordable and clean energy
Openalex Percentile: Top 27%
Wind Turbine Control Systems
0.83
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.