Two-screw osteosynthesis is biomechanically superior to single-screw osteosynthesis for type II odontoid fractures

The data on the use of a one- or two-screw technique (1S, 2S) for ventral osteosynthesis of type II dens fractures are contradictory. The aim was to design an apparatus to mimic the physiological conditions and test stability with 1S, 2S, and a headless compression screw (HCS) for osteosynthesis of artificially created type II odontoid fractures. The apparatus was mounted on a Zwick materials testing machine. A total of 18 C1-2 specimens were stratified into three groups (1S, 2S, HCS). Odontoid fractures were artificially created, and osteosynthesis was performed. Each specimen was tested at loads increasing from 1 to 40 N. Screw loosening was observed visually, by fatigue data, and by a camera tracking system. Analysis of the Zwick data and the camera data revealed a significant higher stability after 2S compared to 1S and HCS treatment (Zwick data: p = 0.021, camera data: p < 0.001), while visible screw loosening showed a superiority of the 2S only over HCS (p = 0.038). The developed apparatus allowed the dynamic study of the atlantoaxial joint with a high approximation to physiological conditions. The results demonstrated superiority of the 2S over the 1S and HCS in biomechanical stability in the treatment of type II odontoid fractures.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2024-08-15
DOI
https://doi.org/10.1038/s41598-024-69905-3
Citations
1
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
0.57

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Two-screw osteosynthesis is biomechanically superior to single-screw osteosynthesis for type II odontoid fractures

Paul Jonathan Roch, Marc‐Pascal Meier, Katharina Jäckle, Friederike Sophie Klockner et al.
1 citations
Scientific Reports
Spinal Fractures and Fixation Techniques
0.57
article

Two-screw osteosynthesis is biomechanically superior to single-screw osteosynthesis for type II odontoid fractures

Paul Jonathan Roch, Marc‐Pascal Meier, Katharina Jäckle, Friederike Sophie Klockner, Lukas Weiser, Wolfgang Lehmann, Elisa Salge, Miguel Angel Bravo Cabrera
article en
1 citations

Abstract

The data on the use of a one- or two-screw technique (1S, 2S) for ventral osteosynthesis of type II dens fractures are contradictory. The aim was to design an apparatus to mimic the physiological conditions and test stability with 1S, 2S, and a headless compression screw (HCS) for osteosynthesis of artificially created type II odontoid fractures. The apparatus was mounted on a Zwick materials testing machine. A total of 18 C1-2 specimens were stratified into three groups (1S, 2S, HCS). Odontoid fractures were artificially created, and osteosynthesis was performed. Each specimen was tested at loads increasing from 1 to 40 N. Screw loosening was observed visually, by fatigue data, and by a camera tracking system. Analysis of the Zwick data and the camera data revealed a significant higher stability after 2S compared to 1S and HCS treatment (Zwick data: p = 0.021, camera data: p < 0.001), while visible screw loosening showed a superiority of the 2S only over HCS (p = 0.038). The developed apparatus allowed the dynamic study of the atlantoaxial joint with a high approximation to physiological conditions. The results demonstrated superiority of the 2S over the 1S and HCS in biomechanical stability in the treatment of type II odontoid fractures.

Scientific ReportsVol. 14(1)
University of Göttingen (DE)
Georg-August-Universität Göttingen
Openalex Percentile: Top 31%
Spinal Fractures and Fixation Techniques
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Two-screw osteosynthesis is biomechanically superior to single-screw osteosynthesis for type II odontoid fractures — Paul Jonathan Roch, Marc‐Pascal Meier, et al. · Scientific Reports (2024) | TGRS Research Map | TGRS