Efficient and Accurate 3D Thickness Measurement in Vessel Wall Imaging: Overcoming Limitations of 2D Approaches Using the Laplacian Method

The clinical significance of measuring vessel wall thickness is widely acknowledged. Recent advancements have enabled high-resolution 3D scans of arteries and precise segmentation of their lumens and outer walls; however, most existing methods for assessing vessel wall thickness are 2D. Despite being valuable, reproducibility and accuracy of 2D techniques depend on the extracted 2D slices. Additionally, these methods fail to fully account for variations in wall thickness in all dimensions. Furthermore, most existing approaches are difficult to be extended into 3D and their measurements lack spatial localization and are primarily confined to lumen boundaries. We advocate for a shift in perspective towards recognizing vessel wall thickness measurement as inherently a 3D challenge and propose adapting the Laplacian method as an outstanding alternative. The Laplacian method is implemented using convolutions, ensuring its efficient and rapid execution on deep learning platforms. Experiments using digital phantoms and vessel wall imaging data are conducted to showcase the accuracy, reproducibility, and localization capabilities of the proposed approach. The proposed method produce consistent outcomes that remain independent of centerlines and 2D slices. Notably, this approach is applicable in both 2D and 3D scenarios. It allows for voxel-wise quantification of wall thickness, enabling precise identification of wall volumes exhibiting abnormal wall thickness. Our research highlights the urgency of transitioning to 3D methodologies for vessel wall thickness measurement. Such a transition not only acknowledges the intricate spatial variations of vessel walls, but also opens doors to more accurate, localized, and insightful diagnostic insights.

Authors

Institutions

Publication Details

Journal
Journal of Cardiovascular Development and Disease
Published
2024-08-15
DOI
https://doi.org/10.3390/jcdd11080249
Citations
1
Primary Topic
Cardiovascular Health and Disease Prevention
Type
article
Field-Weighted Citation Impact
0.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Efficient and Accurate 3D Thickness Measurement in Vessel Wall Imaging: Overcoming Limitations of 2D Approaches Using the Laplacian Method

Chun Yuan, Thomas S. Hatsukami, Niranjan Balu, SeyyedKazem HashemizadehKolowri et al.
1 citations
Journal of Cardiovascular Development and Disease
Cardiovascular Health and Disease Prevention
0.40
article

Efficient and Accurate 3D Thickness Measurement in Vessel Wall Imaging: Overcoming Limitations of 2D Approaches Using the Laplacian Method

Chun Yuan, Thomas S. Hatsukami, Niranjan Balu, SeyyedKazem HashemizadehKolowri, Xiaodong Ma, Marina S. Ferguson, Ebru Yaman Akçiçek, Halit Akçiçek
article en
1 citations

Abstract

The clinical significance of measuring vessel wall thickness is widely acknowledged. Recent advancements have enabled high-resolution 3D scans of arteries and precise segmentation of their lumens and outer walls; however, most existing methods for assessing vessel wall thickness are 2D. Despite being valuable, reproducibility and accuracy of 2D techniques depend on the extracted 2D slices. Additionally, these methods fail to fully account for variations in wall thickness in all dimensions. Furthermore, most existing approaches are difficult to be extended into 3D and their measurements lack spatial localization and are primarily confined to lumen boundaries. We advocate for a shift in perspective towards recognizing vessel wall thickness measurement as inherently a 3D challenge and propose adapting the Laplacian method as an outstanding alternative. The Laplacian method is implemented using convolutions, ensuring its efficient and rapid execution on deep learning platforms. Experiments using digital phantoms and vessel wall imaging data are conducted to showcase the accuracy, reproducibility, and localization capabilities of the proposed approach. The proposed method produce consistent outcomes that remain independent of centerlines and 2D slices. Notably, this approach is applicable in both 2D and 3D scenarios. It allows for voxel-wise quantification of wall thickness, enabling precise identification of wall volumes exhibiting abnormal wall thickness. Our research highlights the urgency of transitioning to 3D methodologies for vessel wall thickness measurement. Such a transition not only acknowledges the intricate spatial variations of vessel walls, but also opens doors to more accurate, localized, and insightful diagnostic insights.

Journal of Cardiovascular Development and DiseaseVol. 11(8)
University of Washington (US), University of Utah (US)
National Institutes of Health
Openalex Percentile: Top 34%
Cardiovascular Health and Disease Prevention
0.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.