Innovative computed tomography based mapping of the surgical posterior tympanotomy: An exploratory study

Robotic devices have recently enhanced cochlear implantation by improving precision resulting in reduced intracochlear damage during electrode insertion. This study aimed to gain first insights into the expected dimensions of the cone-like workspace from the posterior tympanotomy towards the round window membrane. This retrospective chart review analyzed ten postoperative CT scans of adult patients who were implanted with a CI in the past ten years. The dimensions of the cone-like workspace were determined using four landmarks (P1-P4). In the anteroposterior range, P1 and P2 were defined on the edge of the bony layer over the facial nerve and chorda tympani nerve, respectively. In the inferosuperior range, P3 was defined on the bony edge of the incus buttress and P4 was obtained at a distance of 0.45 mm between the facial nerve and the chorda tympani nerve. After selecting the landmarks, the calculations of the dimensions of the surgical access space were done in a standardized coordinate system and presented using descriptive statistics. The cone-like space is limited by two maximal angles, <i>α</i> and <i>β</i>. The average angle <i>α</i> of 19.84 (±3.55) degrees defines the angle towards the round window membrane between P1 and P2. The second average angle <i>β</i> of 53.56 (±10.29) degrees defines the angle towards the round window membrane between P3 and P4. Based on the angles the mean anteroposterior range of 2.25 (±0.42) mm and mean inferosuperior range of 6.73 (±2.42) mm. The distance from the posterior tympanotomy to the round window membrane was estimated at 6.05 (±0.71) mm. These findings present data on the hypothetical maximum workspace in which a future robotically steered insertion tool can be positioned for an optimal automated electrode insertion. A larger sample size is necessary before generalizing these dimensions to a population. Further research including preoperative CT scans is needed for planning robotic-steered cochlear implantation.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-08-01
DOI
https://doi.org/10.1016/j.heliyon.2024.e36335
Citations
1
Primary Topic
Ear Surgery and Otitis Media
Type
article
Field-Weighted Citation Impact
0.58

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative computed tomography based mapping of the surgical posterior tympanotomy: An exploratory study

Lore Kerkhofs, Alexander Geerardyn, Maarten Schoovaerts, Nicolas Verhaert et al.
1 citations
Heliyon
Ear Surgery and Otitis Media
0.58
article

Innovative computed tomography based mapping of the surgical posterior tympanotomy: An exploratory study

Lore Kerkhofs, Alexander Geerardyn, Maarten Schoovaerts, Nicolas Verhaert, Tristan Putzeys, Johannes Devos, Robert Hermans, Brecht Vranken
article en
1 citations

Abstract

Robotic devices have recently enhanced cochlear implantation by improving precision resulting in reduced intracochlear damage during electrode insertion. This study aimed to gain first insights into the expected dimensions of the cone-like workspace from the posterior tympanotomy towards the round window membrane. This retrospective chart review analyzed ten postoperative CT scans of adult patients who were implanted with a CI in the past ten years. The dimensions of the cone-like workspace were determined using four landmarks (P1-P4). In the anteroposterior range, P1 and P2 were defined on the edge of the bony layer over the facial nerve and chorda tympani nerve, respectively. In the inferosuperior range, P3 was defined on the bony edge of the incus buttress and P4 was obtained at a distance of 0.45 mm between the facial nerve and the chorda tympani nerve. After selecting the landmarks, the calculations of the dimensions of the surgical access space were done in a standardized coordinate system and presented using descriptive statistics. The cone-like space is limited by two maximal angles, <i>α</i> and <i>β</i>. The average angle <i>α</i> of 19.84 (±3.55) degrees defines the angle towards the round window membrane between P1 and P2. The second average angle <i>β</i> of 53.56 (±10.29) degrees defines the angle towards the round window membrane between P3 and P4. Based on the angles the mean anteroposterior range of 2.25 (±0.42) mm and mean inferosuperior range of 6.73 (±2.42) mm. The distance from the posterior tympanotomy to the round window membrane was estimated at 6.05 (±0.71) mm. These findings present data on the hypothetical maximum workspace in which a future robotically steered insertion tool can be positioned for an optimal automated electrode insertion. A larger sample size is necessary before generalizing these dimensions to a population. Further research including preoperative CT scans is needed for planning robotic-steered cochlear implantation.

HeliyonVol. 10(16)
KU Leuven (BE)
Fonds Wetenschappelijk Onderzoek, KU Leuven, Vlaamse regering
Openalex Percentile: Top 32%
Ear Surgery and Otitis Media
0.58
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.