Application of Magnetic Separation in Catalyst Reuse Applied in Paracetamol Degradation

This work presents an investigation of the degradation of paracetamol via heterogeneous photocatalysis, aiming to magnetically immobilize the catalyst in a continuous process. Catalyst immobilization was conducted on aggregated flower-like structures. The CoFe2O4@Nb5O2 catalyst was characterized using a Vibrating Sample Magnetometer (VSM). The effects of the magnetic immobilization of the catalyst, flow, residence time, adsorption, and photolysis were evaluated. Additionally, catalyst reuse cycles were analyzed. The results indicated that a longer residence time favors the degradation of paracetamol due to the increase in the contact time of the effluent catalyst. At a flow rate of 20 mL·min−1, a degradation of 27% was obtained. Photolysis and adsorption tests indicated that residence time was not an important factor for paracetamol degradation. For the photolysis test, in the first cycle, the values obtained were in the range of 6.0–8.5%. The adsorption results indicated ~10% removal.

Authors

Institutions

Publication Details

Journal
Magnetism
Published
2024-08-12
DOI
https://doi.org/10.3390/magnetism4030016
Primary Topic
Extraction and Separation Processes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Application of Magnetic Separation in Catalyst Reuse Applied in Paracetamol Degradation

Michel Zampieri Fidelis, Rodrigo Brackmann, Odivaldo Cambraia Alves, Giane Gonçalves Lenzi et al.
Magnetism
Extraction and Separation Processes
article

Application of Magnetic Separation in Catalyst Reuse Applied in Paracetamol Degradation

Michel Zampieri Fidelis, Rodrigo Brackmann, Odivaldo Cambraia Alves, Giane Gonçalves Lenzi, Ângelo Marcelo Tusset, Maria E. K. Fuziki, Eduardo Abreu, Elaine T. de Paula, Jessica R. P. Oliveira
article en

Abstract

This work presents an investigation of the degradation of paracetamol via heterogeneous photocatalysis, aiming to magnetically immobilize the catalyst in a continuous process. Catalyst immobilization was conducted on aggregated flower-like structures. The CoFe2O4@Nb5O2 catalyst was characterized using a Vibrating Sample Magnetometer (VSM). The effects of the magnetic immobilization of the catalyst, flow, residence time, adsorption, and photolysis were evaluated. Additionally, catalyst reuse cycles were analyzed. The results indicated that a longer residence time favors the degradation of paracetamol due to the increase in the contact time of the effluent catalyst. At a flow rate of 20 mL·min−1, a degradation of 27% was obtained. Photolysis and adsorption tests indicated that residence time was not an important factor for paracetamol degradation. For the photolysis test, in the first cycle, the values obtained were in the range of 6.0–8.5%. The adsorption results indicated ~10% removal.

MagnetismVol. 4(3)
Universidade Estadual de Maringá (BR), Universidade Tecnológica Federal do Paraná (BR), Universidade Federal Fluminense (BR)
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Clean water and sanitation
Openalex Percentile: Top 87%
Extraction and Separation Processes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Application of Magnetic Separation in Catalyst Reuse Applied in Paracetamol Degradation — Michel Zampieri Fidelis, Rodrigo Brackmann, et al. · Magnetism (2024) | TGRS Research Map | TGRS