Fully digitalized triple-energy x-ray computed tomography with high spatial resolutions using beam hardening

To regulate the effective photon energy with a constant tube voltage and to perform enhanced K-edge x-ray imaging, we built a prototype fully digitalized triple-energy x-ray computed tomography (TECT) scanner utilizing beam hardening. An object on the turntable is irradiated by a 0.1-mm-focus x-ray tube at 1.4-time-magnification. 720 raw radiograms are obtained using a flat panel detector, and 512 tomograms are reconstructed. With an increasing digital amplification factor, the gray raw-density projections obtained using low-energy-photon absorption disappeared at a constant maximum raw density, and the effective energy was increased by x-ray beam hardening. TECT was performed at digital amplifier factors below 3.0, and the effective energy increased with increasing amplification factors. In particular, fine blood vessels were visible using gadolinium-K-edge CT.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-08-01
DOI
https://doi.org/10.1063/5.0207543
Citations
1
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.18

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fully digitalized triple-energy x-ray computed tomography with high spatial resolutions using beam hardening

Osahiko Hagiwara, Sohei Yoshida, Kazuki Ito, Hodaka Moriyama et al.
1 citations
Review of Scientific Instruments
Advanced X-ray and CT Imaging
0.18
article

Fully digitalized triple-energy x-ray computed tomography with high spatial resolutions using beam hardening

Osahiko Hagiwara, Sohei Yoshida, Kazuki Ito, Hodaka Moriyama, Manabu Watanabe, Eiichi Sato, Toshiyuki Enomoto
article en
1 citations

Abstract

To regulate the effective photon energy with a constant tube voltage and to perform enhanced K-edge x-ray imaging, we built a prototype fully digitalized triple-energy x-ray computed tomography (TECT) scanner utilizing beam hardening. An object on the turntable is irradiated by a 0.1-mm-focus x-ray tube at 1.4-time-magnification. 720 raw radiograms are obtained using a flat panel detector, and 512 tomograms are reconstructed. With an increasing digital amplification factor, the gray raw-density projections obtained using low-energy-photon absorption disappeared at a constant maximum raw density, and the effective energy was increased by x-ray beam hardening. TECT was performed at digital amplifier factors below 3.0, and the effective energy increased with increasing amplification factors. In particular, fine blood vessels were visible using gadolinium-K-edge CT.

Review of Scientific InstrumentsVol. 95(8)
Toho University (JP), Iwate Medical University (JP), Toho University Ohashi Medical Center (JP)
Ministry of Education, Culture, Sports, Science and Technology
Affordable and clean energy
Openalex Percentile: Top 54%
Advanced X-ray and CT Imaging
0.18
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Fully digitalized triple-energy x-ray computed tomography with high spatial resolutions using beam hardening — Osahiko Hagiwara, Sohei Yoshida, et al. · Review of Scientific Instruments (2024) | TGRS Research Map | TGRS