Experimental evaluation of the influence of the diffuser inlet to nozzle exit cross sectional area ratio on pressure oscillation in a high-altitude test facility

The ratio of diffuser inlet to nozzle exit area (Ad/Ae) is one of the most important parameters in designing and evaluating the performance of a high-altitude test facility (HATF). Typically, at motor pressures near start or operating pressure of the diffuser, the vacuum chamber pressure oscillates at a high Ad/Ae, which may be dangerous for the HATF. In the present study, the effect of the Ad/Ae on the starting and breakdown performance of a second throat exhaust diffuser (STED) has been investigated experimentally using a HATF supplied by high-pressure cold air apparatus. Upon examining the overall performance of the diffuser, it is observed that with an increase in Ad/Ae, the oblique sealing shock wave at the diffuser inlet undergoes significant changes in location and strength. This leads to a further reduction of the flow total pressure and a stronger separation of the flow along the diffuser. Consequently, flow instability arises during starting or breakdown phases near the STED starting or operating pressure. By frequency analysis, it is observed that as Ad/Ae increases, the number of oscillatory modes of the vacuum chamber pressure increases and the dominant frequency of the oscillations in these transient situations becomes larger. Additionally, there is a significant decrease in nozzle pressure related to the onset of pressure oscillations. Furthermore, with an increase in Ad/Ae from 1.27 to 7.81, the minimum starting pressure and breakdown pressure of STED increase by 20.33% and 28.47%, respectively. Also, the hysteresis range in performance of STED vanishes at high Ad/Ae values.

Authors

Institutions

Publication Details

Journal
Physics of Fluids
Published
2024-08-01
DOI
https://doi.org/10.1063/5.0217385
Citations
5
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
1.06
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental evaluation of the influence of the diffuser inlet to nozzle exit cross sectional area ratio on pressure oscillation in a high-altitude test facility

Mohammad Farahani, Nematollah Fouladi, A. A. Nojoumi, A. R. Parsa Delivand
5 citations
Physics of Fluids
Refrigeration and Air Conditioning Technologies
1.06
article

Experimental evaluation of the influence of the diffuser inlet to nozzle exit cross sectional area ratio on pressure oscillation in a high-altitude test facility

Mohammad Farahani, Nematollah Fouladi, A. A. Nojoumi, A. R. Parsa Delivand
article en
5 citations

Abstract

The ratio of diffuser inlet to nozzle exit area (Ad/Ae) is one of the most important parameters in designing and evaluating the performance of a high-altitude test facility (HATF). Typically, at motor pressures near start or operating pressure of the diffuser, the vacuum chamber pressure oscillates at a high Ad/Ae, which may be dangerous for the HATF. In the present study, the effect of the Ad/Ae on the starting and breakdown performance of a second throat exhaust diffuser (STED) has been investigated experimentally using a HATF supplied by high-pressure cold air apparatus. Upon examining the overall performance of the diffuser, it is observed that with an increase in Ad/Ae, the oblique sealing shock wave at the diffuser inlet undergoes significant changes in location and strength. This leads to a further reduction of the flow total pressure and a stronger separation of the flow along the diffuser. Consequently, flow instability arises during starting or breakdown phases near the STED starting or operating pressure. By frequency analysis, it is observed that as Ad/Ae increases, the number of oscillatory modes of the vacuum chamber pressure increases and the dominant frequency of the oscillations in these transient situations becomes larger. Additionally, there is a significant decrease in nozzle pressure related to the onset of pressure oscillations. Furthermore, with an increase in Ad/Ae from 1.27 to 7.81, the minimum starting pressure and breakdown pressure of STED increase by 20.33% and 28.47%, respectively. Also, the hysteresis range in performance of STED vanishes at high Ad/Ae values.

Physics of FluidsVol. 36(8)
Sharif University of Technology (IR), Aerospace Research Institute (IR)
Openalex Percentile: Top 27%
Refrigeration and Air Conditioning Technologies
1.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.