The influence of occupant control behaviour on thermal comfort under different heating charging modes in residential buildings in cold regions

In China's central heating, there are two modes for calculating heating costs, which are divided into Charging by flow mode which charges according to the amount of use and Charging by area mode which charges according to the floor area. The Charging by flow mode has been increasingly adopted by numerous urban central heating buildings. Thus it is worth investigating whether occupants experience varying levels of thermal comfort under these two modes. To address this, a field test and subjective questionnaire survey were conducted on residential buildings in cold regions of China during the heating season. The study assessed 134 residential occupants utilizing radiator heating, comprising 66 in Charging by area and 68 in Charging by flow modes. A collection of 1206 valid data points was obtained, with 609 in Charging by area mode and 597 in Charging by flow mode. The findings reveal noteworthy disparities in the duration, area, and strength of heating equipment usage between the two modes. While there are no marked variances in the interior and exterior environmental conditions under both modes, residents in the Charging by flow mode experience enhanced thermal comfort, acceptability and expectation, as well as better air quality satisfaction. Perceived control can greatly enhance individuals' thermal sensation in temperatures below 18 °C and above 24 °C. The impact of perceived control on thermal expectation is linear with temperature adjustments. The heightened degree of sensing control in Charging by flow mode lowers residents' expectations of high temperatures, broadens the range of acceptable low temperatures and accomplishes energy conservation and carbon reduction while ensuring optimal comfort.

Authors

Institutions

Publication Details

Journal
Heliyon
Published
2024-08-01
DOI
https://doi.org/10.1016/j.heliyon.2024.e36328
Citations
3
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.80

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The influence of occupant control behaviour on thermal comfort under different heating charging modes in residential buildings in cold regions

Linxiao Xie, Haiyan Yan, D. H. Chow, Xu Chen et al.
3 citations
Heliyon
Building Energy and Comfort Optimization
0.80
article

The influence of occupant control behaviour on thermal comfort under different heating charging modes in residential buildings in cold regions

Linxiao Xie, Haiyan Yan, D. H. Chow, Xu Chen, Менг Ли
article en
3 citations

Abstract

In China's central heating, there are two modes for calculating heating costs, which are divided into Charging by flow mode which charges according to the amount of use and Charging by area mode which charges according to the floor area. The Charging by flow mode has been increasingly adopted by numerous urban central heating buildings. Thus it is worth investigating whether occupants experience varying levels of thermal comfort under these two modes. To address this, a field test and subjective questionnaire survey were conducted on residential buildings in cold regions of China during the heating season. The study assessed 134 residential occupants utilizing radiator heating, comprising 66 in Charging by area and 68 in Charging by flow modes. A collection of 1206 valid data points was obtained, with 609 in Charging by area mode and 597 in Charging by flow mode. The findings reveal noteworthy disparities in the duration, area, and strength of heating equipment usage between the two modes. While there are no marked variances in the interior and exterior environmental conditions under both modes, residents in the Charging by flow mode experience enhanced thermal comfort, acceptability and expectation, as well as better air quality satisfaction. Perceived control can greatly enhance individuals' thermal sensation in temperatures below 18 °C and above 24 °C. The impact of perceived control on thermal expectation is linear with temperature adjustments. The heightened degree of sensing control in Charging by flow mode lowers residents' expectations of high temperatures, broadens the range of acceptable low temperatures and accomplishes energy conservation and carbon reduction while ensuring optimal comfort.

HeliyonVol. 10(16)
University of Liverpool (GB), Henan Polytechnic University (CN)
National Natural Science Foundation of China, National Aerospace Science Foundation of China, Innovation Scientists and Technicians Troop Construction Projects of Henan Province
Sustainable cities and communities
Openalex Percentile: Top 29%
Building Energy and Comfort Optimization
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.