Study on the Mechanical Properties and Bearing Capacity of Ultra-High Performance Concrete Members

It is used as pier column members in viaducts, urban overpasses and industrial and civil building structures. In practical engineering, short columns or ultra-short columns with relatively small shear span may be formed, and shear failure may become the control condition for components and even structural damage. Under the action of large concentrated load or strong earthquake, the key parts of the high-rise structure and beam bridge system are obviously shear, leading to the serious brittleness and poor ductility of the components, which leads to serious structural continuity collapse, and then brings the loss of life and property. Therefore, it is important to study the shear properties of corrugated concrete members and to study the mechanical properties of components under complex load coupling. TRC comparison, 10 mm incision 100 mm from both ends. The specimen is equipped with 8 HRB400 longitudinal bars of 12 mm diameter along the length direction, the center of the longitudinal bars is 105 mm from the center of the specimen, and the steel content is 1.84%; the longitudinal bars with HPB300 stirrup of 100 along the axial direction, and the steel content of the stirrups is 0.68%. The results show that because the corrugated steel pipe can provide sufficient constraint for the internal core concrete and steel, the corrugated CFCT members have better ductility than the constrained concrete members under the small shear span ratio, which can effectively delay the occurrence of brittle shear failure. The curved shear test study of 12 corrugated concrete filled steel tube specimens was carried out, and the test phenomenon and failure mode of the components under different shear span ratio conditions were compared and analyzed. The study shows that when the shear span ratio is not greater than 0.2, the specimen shear error is obvious, mainly shear failure; when the shear span ratio is between 0.2 and 2.0, the specimen bending shear failure. With the increase of the shear span ratio, the specimen failure form is closer to the bending failure.

Authors

Institutions

Publication Details

Journal
European Journal of Computational Mechanics
Published
2024-08-12
DOI
https://doi.org/10.13052/ejcm2642-2085.3344
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study on the Mechanical Properties and Bearing Capacity of Ultra-High Performance Concrete Members

Jing Hua Diao, Xingwang Yin, Ang Zhang
European Journal of Computational Mechanics
Structural Behavior of Reinforced Concrete
article

Study on the Mechanical Properties and Bearing Capacity of Ultra-High Performance Concrete Members

Jing Hua Diao, Xingwang Yin, Ang Zhang
article en

Abstract

It is used as pier column members in viaducts, urban overpasses and industrial and civil building structures. In practical engineering, short columns or ultra-short columns with relatively small shear span may be formed, and shear failure may become the control condition for components and even structural damage. Under the action of large concentrated load or strong earthquake, the key parts of the high-rise structure and beam bridge system are obviously shear, leading to the serious brittleness and poor ductility of the components, which leads to serious structural continuity collapse, and then brings the loss of life and property. Therefore, it is important to study the shear properties of corrugated concrete members and to study the mechanical properties of components under complex load coupling. TRC comparison, 10 mm incision 100 mm from both ends. The specimen is equipped with 8 HRB400 longitudinal bars of 12 mm diameter along the length direction, the center of the longitudinal bars is 105 mm from the center of the specimen, and the steel content is 1.84%; the longitudinal bars with HPB300 stirrup of 100 along the axial direction, and the steel content of the stirrups is 0.68%. The results show that because the corrugated steel pipe can provide sufficient constraint for the internal core concrete and steel, the corrugated CFCT members have better ductility than the constrained concrete members under the small shear span ratio, which can effectively delay the occurrence of brittle shear failure. The curved shear test study of 12 corrugated concrete filled steel tube specimens was carried out, and the test phenomenon and failure mode of the components under different shear span ratio conditions were compared and analyzed. The study shows that when the shear span ratio is not greater than 0.2, the specimen shear error is obvious, mainly shear failure; when the shear span ratio is between 0.2 and 2.0, the specimen bending shear failure. With the increase of the shear span ratio, the specimen failure form is closer to the bending failure.

European Journal of Computational Mechanics
Henan Polytechnic University (CN)
Sustainable cities and communities
Openalex Percentile: Top 87%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Study on the Mechanical Properties and Bearing Capacity of Ultra-High Performance Concrete Members — Jing Hua Diao, Xingwang Yin, et al. · European Journal of Computational Mechanics (2024) | TGRS Research Map | TGRS