A temperature-compensated CO2 detection system based on non-dispersive infrared spectral technology

The concentration of carbon dioxide (CO2) is an important indicator for coal mine safety. Real-time monitoring of CO2 concentration is of great importance for taking actions in advance to avoid the occurrence of potential accidents. To address the issues of poor portability and high cost associated with existing coal mine CO2 detection equipment, this paper develops a miniaturized CO2 detection system based on non-dispersive infrared (NDIR) technology. This sensor integrates an infrared light source and a dual-channel pyroelectric detector into a reflective gas chamber, thereby achieving an extended optical path and higher system sensitivity within limited space. Meanwhile, the noise interference was greatly mitigated by using hardware and software filtering techniques. Based on principle analysis, the Lambert-Beer law was parametrically corrected, and then, a model relationship between the dual-channel voltage ratio and concentration was established. In addition, temperature compensation for zero and span values was introduced to improve the adaptability of the detection results to temperature changes. Testing results indicate that the developed detection system can realize CO2 measurement in the concentration range of 0 to 50 000 ppm within a temperature range of 0-40 °C, with a maximum detection error of less than 0.12% and a repeatability deviation of less than 1.04%. During a stability test for 12 h, the maximum concentration drift is 0.07%, indicating that the developed system meets the requirements for monitoring CO2 safety in coal mines.

Authors

Institutions

Publication Details

Journal
Review of Scientific Instruments
Published
2024-08-01
DOI
https://doi.org/10.1063/5.0203277
Citations
11
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
2.65

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A temperature-compensated CO2 detection system based on non-dispersive infrared spectral technology

Qiulin Tan, Ke Long Yu, Penghui Zhang, Xiaopeng Yang et al.
11 citations
Review of Scientific Instruments
Spectroscopy and Laser Applications
2.65
article

A temperature-compensated CO2 detection system based on non-dispersive infrared spectral technology

Qiulin Tan, Ke Long Yu, Penghui Zhang, Xiaopeng Yang, Lei Zhang, Yijie Wang
article en
11 citations

Abstract

The concentration of carbon dioxide (CO2) is an important indicator for coal mine safety. Real-time monitoring of CO2 concentration is of great importance for taking actions in advance to avoid the occurrence of potential accidents. To address the issues of poor portability and high cost associated with existing coal mine CO2 detection equipment, this paper develops a miniaturized CO2 detection system based on non-dispersive infrared (NDIR) technology. This sensor integrates an infrared light source and a dual-channel pyroelectric detector into a reflective gas chamber, thereby achieving an extended optical path and higher system sensitivity within limited space. Meanwhile, the noise interference was greatly mitigated by using hardware and software filtering techniques. Based on principle analysis, the Lambert-Beer law was parametrically corrected, and then, a model relationship between the dual-channel voltage ratio and concentration was established. In addition, temperature compensation for zero and span values was introduced to improve the adaptability of the detection results to temperature changes. Testing results indicate that the developed detection system can realize CO2 measurement in the concentration range of 0 to 50 000 ppm within a temperature range of 0-40 °C, with a maximum detection error of less than 0.12% and a repeatability deviation of less than 1.04%. During a stability test for 12 h, the maximum concentration drift is 0.07%, indicating that the developed system meets the requirements for monitoring CO2 safety in coal mines.

Review of Scientific InstrumentsVol. 95(8)
North University of China (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 10%
Spectroscopy and Laser Applications
2.65
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.