Microfluidic assay devices integrated with Au nanorods for rapid and sensitive detection of cardiac troponin I

Abstract We present a microfluidic assay device integrated with Au nanorods for rapid and sensitive detection of Cardiac troponin I (cTnI), the current gold standard biomarker for diagnosing acute myocardial infarction. The Au nanorods, fabricated using oblique angle deposition (OAD), significantly enhance fluorescent signals, thereby eliminating the need for high-resolution lithography technologies. Leveraging this device, rapid and sensitive detection of cTnI is realized with a limit of detection (LOD) of 6.9 pg mL −1 within 6 minutes, referring to a sensitivity enhancement of 4000-fold compared to glass substrates. Given its simple fabrication method, ease of operation, and highly sensitive immunoassay performance, this device holds great potential for clinical and point-of-care testing (POCT) applications.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-08-01
DOI
https://doi.org/10.1088/1742-6596/2809/1/012021
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidic assay devices integrated with Au nanorods for rapid and sensitive detection of cardiac troponin I

Xi Yang, Zhen Cao, Jiaqi Lu, Guangyang Li et al.
Journal of Physics Conference Series
Biosensors and Analytical Detection
article

Microfluidic assay devices integrated with Au nanorods for rapid and sensitive detection of cardiac troponin I

Xi Yang, Zhen Cao, Jiaqi Lu, Guangyang Li, Lingyue Xue, Xuefeng Xu, MingZhu Xu, A.C. Xiang, Sixing Hu
article en

Abstract

Abstract We present a microfluidic assay device integrated with Au nanorods for rapid and sensitive detection of Cardiac troponin I (cTnI), the current gold standard biomarker for diagnosing acute myocardial infarction. The Au nanorods, fabricated using oblique angle deposition (OAD), significantly enhance fluorescent signals, thereby eliminating the need for high-resolution lithography technologies. Leveraging this device, rapid and sensitive detection of cTnI is realized with a limit of detection (LOD) of 6.9 pg mL −1 within 6 minutes, referring to a sensitivity enhancement of 4000-fold compared to glass substrates. Given its simple fabrication method, ease of operation, and highly sensitive immunoassay performance, this device holds great potential for clinical and point-of-care testing (POCT) applications.

Journal of Physics Conference SeriesVol. 2809(1)
Zhejiang University (CN)
Openalex Percentile: Top 88%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Microfluidic assay devices integrated with Au nanorods for rapid and sensitive detection of cardiac troponin I — Xi Yang, Zhen Cao, et al. · Journal of Physics Conference Series (2024) | TGRS Research Map | TGRS