Quantification of Aortic Valve Fibrotic and Calcific Tissue from CTA: Prospective Comparison with Histology

Background Quantifying the fibrotic and calcific composition of the aortic valve at CT angiography (CTA) can be useful for assessing disease severity and outcomes of patients with aortic stenosis (AS); however, it has not yet been validated against quantitative histologic findings. Purpose To compare quantification of aortic valve fibrotic and calcific tissue composition at CTA versus histologic examination. Materials and Methods This prospective study included patients who underwent CTA before either surgical aortic valve replacement for AS or orthotopic heart transplant (controls) at two centers between January 2022 and April 2023. At CTA, fibrotic and calcific tissue composition were quantified using automated Gaussian mixture modeling applied to the density of aortic valve tissue components, calculated as [(volume/total tissue volume) × 100]. For histologic evaluation, explanted valve cusps were stained with Movat pentachrome as well as hematoxylin and eosin. For each cusp, three 5-µm slices were obtained. Fibrotic and calcific tissue composition were quantified using a validated artificial intelligence tool and averaged across the aortic valve. Correlations were assessed using the Spearman rank correlation coefficient. Intermodality and interobserver variability were measured using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results Twenty-nine participants (mean age, 63 years ± 10 [SD]; 23 male) were evaluated: 19 with severe AS, five with moderate AS, and five controls. Fibrocalcific tissue composition strongly correlated with histologic findings (<i>r</i> = 0.92; <i>P</i> < .001). The agreement between CTA and histologic findings for fibrocalcific tissue quantification was excellent (ICC, 0.94; <i>P</i> = .001), with underestimation of fibrotic composition at CTA (bias, -4.9%; 95% limits of agreement [LoA]: -18.5%, 8.7%). Finally, there was excellent interobserver repeatability for fibrotic (ICC, 0.99) and calcific (ICC, 0.99) aortic valve tissue volume measurements, with no evidence of a difference in measurements between readers (bias, -0.04 cm<sup>3</sup> [95% LoA: -0.27 cm<sup>3</sup>, 0.19 cm<sup>3</sup>] and 0.02 cm<sup>3</sup> [95% LoA: -0.14 cm<sup>3</sup>, 0.19 cm<sup>3</sup>], respectively). Conclusion In a direct comparison, standardized quantitative aortic valve tissue characterization at CTA showed excellent concordance with histologic findings and demonstrated interobserver reproducibility. Clinical trial registration no. NCT06136689 Published under a CC BY 4.0 license. <i>Supplemental material is available for this article.</i> See also the editorial by Almeida in this issue.

Authors

Institutions

Publication Details

Journal
Radiology
Published
2024-08-01
DOI
https://doi.org/10.1148/radiol.240229
Citations
13
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
5.23

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantification of Aortic Valve Fibrotic and Calcific Tissue from CTA: Prospective Comparison with Histology

Marek Jemielity, Joanna Nawara-Skipirzepa, Kajetan Grodecki, Bartłomiej Perek et al.
13 citations
Radiology
Cardiac Valve Diseases and Treatments
5.23
article

Quantification of Aortic Valve Fibrotic and Calcific Tissue from CTA: Prospective Comparison with Histology

Marek Jemielity, Joanna Nawara-Skipirzepa, Kajetan Grodecki, Bartłomiej Perek, Barbara Górnicka, Wojciech Wojakowski, Jolien Geers, Hasan Jilaihawi, Janusz Kochman, Tomasz Kamil Urbanowicz, Raj Makkar, Damini Dey, Radosław Gocoł, Jacek Kwieciński, Anna Olasińska‐Wiśniewska, Zenon Huczek, Agata Cyran, Balaji Tamarappoo, Piotr J. Slomka
article en
13 citations

Abstract

Background Quantifying the fibrotic and calcific composition of the aortic valve at CT angiography (CTA) can be useful for assessing disease severity and outcomes of patients with aortic stenosis (AS); however, it has not yet been validated against quantitative histologic findings. Purpose To compare quantification of aortic valve fibrotic and calcific tissue composition at CTA versus histologic examination. Materials and Methods This prospective study included patients who underwent CTA before either surgical aortic valve replacement for AS or orthotopic heart transplant (controls) at two centers between January 2022 and April 2023. At CTA, fibrotic and calcific tissue composition were quantified using automated Gaussian mixture modeling applied to the density of aortic valve tissue components, calculated as [(volume/total tissue volume) × 100]. For histologic evaluation, explanted valve cusps were stained with Movat pentachrome as well as hematoxylin and eosin. For each cusp, three 5-µm slices were obtained. Fibrotic and calcific tissue composition were quantified using a validated artificial intelligence tool and averaged across the aortic valve. Correlations were assessed using the Spearman rank correlation coefficient. Intermodality and interobserver variability were measured using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results Twenty-nine participants (mean age, 63 years ± 10 [SD]; 23 male) were evaluated: 19 with severe AS, five with moderate AS, and five controls. Fibrocalcific tissue composition strongly correlated with histologic findings (<i>r</i> = 0.92; <i>P</i> < .001). The agreement between CTA and histologic findings for fibrocalcific tissue quantification was excellent (ICC, 0.94; <i>P</i> = .001), with underestimation of fibrotic composition at CTA (bias, -4.9%; 95% limits of agreement [LoA]: -18.5%, 8.7%). Finally, there was excellent interobserver repeatability for fibrotic (ICC, 0.99) and calcific (ICC, 0.99) aortic valve tissue volume measurements, with no evidence of a difference in measurements between readers (bias, -0.04 cm<sup>3</sup> [95% LoA: -0.27 cm<sup>3</sup>, 0.19 cm<sup>3</sup>] and 0.02 cm<sup>3</sup> [95% LoA: -0.14 cm<sup>3</sup>, 0.19 cm<sup>3</sup>], respectively). Conclusion In a direct comparison, standardized quantitative aortic valve tissue characterization at CTA showed excellent concordance with histologic findings and demonstrated interobserver reproducibility. Clinical trial registration no. NCT06136689 Published under a CC BY 4.0 license. <i>Supplemental material is available for this article.</i> See also the editorial by Almeida in this issue.

RadiologyVol. 312(2)
Medical University of Warsaw (PL)
Fundacja na rzecz Nauki Polskiej, Polskiego Towarzystwa Kardiologicznego, Narodowa Agencja Wymiany Akademickiej, National Heart, Lung, and Blood Institute
Openalex Percentile: Top 4%
Cardiac Valve Diseases and Treatments
5.23
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.