A self-reciprocity calibration of spherical transducers using boundary reflection in a spherical shell

A self-reciprocity method is described for calibrating a spherical transducer in a spherical shell. The reciprocity constant is calculated using Green's function and the electroacoustic reciprocal principle in the spherical shell. A sensitivity correction is developed by calculating the transducer's receiving force in different fields. An experimental measurement setup is described to calibrate transducers with diameters of 20 and 30 mm in the frequency range from 25 to 63 kHz, calibrated in a 500 mm diameter spherical shell with a thickness of 2 mm. The largest discrepancy in calibration results between the self-reciprocity and three-transducer spherical-wave reciprocity method is around -1.4 dB. The self-reciprocity calibration method, with a smaller volume required than the three-transducer spherical-wave reciprocity method, has a potential advantage in calibrating the transducer at high hydrostatic pressure and varying water temperatures.

Authors

Institutions

Publication Details

Journal
The Journal of the Acoustical Society of America
Published
2024-08-01
DOI
https://doi.org/10.1121/10.0028194
Citations
1
Primary Topic
Ultrasonics and Acoustic Wave Propagation
Type
article
Field-Weighted Citation Impact
0.27
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A self-reciprocity calibration of spherical transducers using boundary reflection in a spherical shell

Jun Zhang, Liuqing Yang
1 citations
The Journal of the Acoustical Society of America
Ultrasonics and Acoustic Wave Propagation
0.27
article

A self-reciprocity calibration of spherical transducers using boundary reflection in a spherical shell

Jun Zhang, Liuqing Yang
article en
1 citations

Abstract

A self-reciprocity method is described for calibrating a spherical transducer in a spherical shell. The reciprocity constant is calculated using Green's function and the electroacoustic reciprocal principle in the spherical shell. A sensitivity correction is developed by calculating the transducer's receiving force in different fields. An experimental measurement setup is described to calibrate transducers with diameters of 20 and 30 mm in the frequency range from 25 to 63 kHz, calibrated in a 500 mm diameter spherical shell with a thickness of 2 mm. The largest discrepancy in calibration results between the self-reciprocity and three-transducer spherical-wave reciprocity method is around -1.4 dB. The self-reciprocity calibration method, with a smaller volume required than the three-transducer spherical-wave reciprocity method, has a potential advantage in calibrating the transducer at high hydrostatic pressure and varying water temperatures.

The Journal of the Acoustical Society of AmericaVol. 156(2)
Qingdao University (CN), Harbin Engineering University (CN), Hangzhou Institute of Applied Acoustics (CN)
Clean water and sanitation
Openalex Percentile: Top 51%
Ultrasonics and Acoustic Wave Propagation
0.27
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.