RVDLAHA: An RISC-V DLA Hardware Architecture for On-Device Real-Time Seizure Detection and Personalization in Wearable Applications

Epilepsy is a globally distributed chronic neurological disorder that may pose a threat to life without warning. Therefore, the use of wearable devices for real-time detection and treatment of epilepsy is crucial. Additionally, personalizing disease detection algorithms for individual users is also a challenge in clinical applications. Some studies have proposed seizure detection algorithms with convolutional neural networks (CNNs) and programmable hardware architectures for speeding up the process of CNN inference. However, personalizing seizure detection algorithms could still not be performed on these hardware architectures. Consequently, this study proposes three key contributions to address the challenges: a real-time seizure detection and personalization algorithm, a programmable reduced instruction set computer-V (RISC-V) deep learning accelerator (DLA) hardware architecture (RVDLAHA), and a dedicated RISC-V DLA (RVDLA) compiler. In animal experiments with lab rats, the proposed CNN-based seizure detection algorithm obtains an accuracy of 99.5% for a 32-bit floating point and an accuracy of 99.3% for a 16-bit fixed point. Additionally, the proposed personalization algorithm increases the testing accuracy across different databases from 85.0% to 92.9%. The RVDLAHA is implemented on Xilinx PYNQ-Z2, with a power consumption of only 0.107 W at an operating frequency of 1 MHz. Each step, including raw data input, preprocessing, detection, and personalization, requires only 17.8, 1.0, 1.1, and 1.3 ms, respectively. With the hardware architecture, the seizure detection and personalization algorithm can provide on-device real-time monitoring.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Biomedical Circuits and Systems
Published
2024-08-13
DOI
https://doi.org/10.1109/tbcas.2024.3442250
Citations
3
Primary Topic
EEG and Brain-Computer Interfaces
Type
article
Field-Weighted Citation Impact
1.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RVDLAHA: An RISC-V DLA Hardware Architecture for On-Device Real-Time Seizure Detection and Personalization in Wearable Applications

Ming-Yueh Ku, Shuenn-Yuh Lee, Chou‐Ching K. Lin, Yen-Hsing Tsai
3 citations
IEEE Transactions on Biomedical Circuits and Systems
EEG and Brain-Computer Interfaces
1.03
article

RVDLAHA: An RISC-V DLA Hardware Architecture for On-Device Real-Time Seizure Detection and Personalization in Wearable Applications

Ming-Yueh Ku, Shuenn-Yuh Lee, Chou‐Ching K. Lin, Yen-Hsing Tsai
article en
3 citations

Abstract

Epilepsy is a globally distributed chronic neurological disorder that may pose a threat to life without warning. Therefore, the use of wearable devices for real-time detection and treatment of epilepsy is crucial. Additionally, personalizing disease detection algorithms for individual users is also a challenge in clinical applications. Some studies have proposed seizure detection algorithms with convolutional neural networks (CNNs) and programmable hardware architectures for speeding up the process of CNN inference. However, personalizing seizure detection algorithms could still not be performed on these hardware architectures. Consequently, this study proposes three key contributions to address the challenges: a real-time seizure detection and personalization algorithm, a programmable reduced instruction set computer-V (RISC-V) deep learning accelerator (DLA) hardware architecture (RVDLAHA), and a dedicated RISC-V DLA (RVDLA) compiler. In animal experiments with lab rats, the proposed CNN-based seizure detection algorithm obtains an accuracy of 99.5% for a 32-bit floating point and an accuracy of 99.3% for a 16-bit fixed point. Additionally, the proposed personalization algorithm increases the testing accuracy across different databases from 85.0% to 92.9%. The RVDLAHA is implemented on Xilinx PYNQ-Z2, with a power consumption of only 0.107 W at an operating frequency of 1 MHz. Each step, including raw data input, preprocessing, detection, and personalization, requires only 17.8, 1.0, 1.1, and 1.3 ms, respectively. With the hardware architecture, the seizure detection and personalization algorithm can provide on-device real-time monitoring.

IEEE Transactions on Biomedical Circuits and SystemsVol. 19(1)
National Cheng Kung University Hospital (TW), National Cheng Kung University (TW)
Openalex Percentile: Top 25%
EEG and Brain-Computer Interfaces
1.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.