Improving Spatial Resolution and Correcting Surface Topography in Portable Macro-XRF Imaging Devices

In macro X-ray fluorescence (MA-XRF) imaging devices, a larger beam size leads to worse spatial resolution, and the surface topography can produce shadow patterns in the image that hinder its analysis. In this study, a portable MA-XRF imaging device is constructed, and the performance of the device is measured. Three image reconstruction algorithms are introduced, including compressive sensing, L0-regularized intensity and gradient prior (L0RIGP), and blind deconvolution (BD), to compare the image reconstruction of the USAF 1951 resolution test target. The results show that the BD algorithm outperformed the other two methods, achieving up to a 35% improvement in spatial resolution, a 24.2% enhancement in image signal-to-noise ratio, and an optimal spatial resolution of 0.36 mm (1.39 lp/mm). An intensity theoretical calculation model of XRF based on the sample surface topography is established. The copper map of a “5 Jiao” coin is corrected and the mean deviation decreased by 5.7%. Finally, a piece of lapis lazuli is analyzed, and the quality of the element maps of K, Ca, and Sr is improved by the surface topography correction and image reconstruction, with spatial resolutions increasing by 36.1%, 34.4%, and 33.5%, respectively. The research in this article demonstrates that the MA-XRF imaging device based on spatial resolution optimization and surface topography correction algorithms has promising applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Nuclear Science
Published
2024-08-13
DOI
https://doi.org/10.1109/tns.2024.3443124
Citations
4
Primary Topic
Advanced X-ray Imaging Techniques
Type
article
Field-Weighted Citation Impact
2.43

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Spatial Resolution and Correcting Surface Topography in Portable Macro-XRF Imaging Devices

Ning Huang, Jie He, Zhu An, Peng Wang et al.
4 citations
IEEE Transactions on Nuclear Science
Advanced X-ray Imaging Techniques
2.43
article

Improving Spatial Resolution and Correcting Surface Topography in Portable Macro-XRF Imaging Devices

Ning Huang, Jie He, Zhu An, Peng Wang, Jiamei Wang, Ze He, Jingxi Yuan, Hai Wang
article en
4 citations

Abstract

In macro X-ray fluorescence (MA-XRF) imaging devices, a larger beam size leads to worse spatial resolution, and the surface topography can produce shadow patterns in the image that hinder its analysis. In this study, a portable MA-XRF imaging device is constructed, and the performance of the device is measured. Three image reconstruction algorithms are introduced, including compressive sensing, L0-regularized intensity and gradient prior (L0RIGP), and blind deconvolution (BD), to compare the image reconstruction of the USAF 1951 resolution test target. The results show that the BD algorithm outperformed the other two methods, achieving up to a 35% improvement in spatial resolution, a 24.2% enhancement in image signal-to-noise ratio, and an optimal spatial resolution of 0.36 mm (1.39 lp/mm). An intensity theoretical calculation model of XRF based on the sample surface topography is established. The copper map of a “5 Jiao” coin is corrected and the mean deviation decreased by 5.7%. Finally, a piece of lapis lazuli is analyzed, and the quality of the element maps of K, Ca, and Sr is improved by the surface topography correction and image reconstruction, with spatial resolutions increasing by 36.1%, 34.4%, and 33.5%, respectively. The research in this article demonstrates that the MA-XRF imaging device based on spatial resolution optimization and surface topography correction algorithms has promising applications.

IEEE Transactions on Nuclear ScienceVol. 71(9)
Sichuan University (CN)
Tianjin Science and Technology Program
Openalex Percentile: Top 12%
Advanced X-ray Imaging Techniques
2.43
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving Spatial Resolution and Correcting Surface Topography in Portable Macro-XRF Imaging Devices — Ning Huang, Jie He, et al. · IEEE Transactions on Nuclear Science (2024) | TGRS Research Map | TGRS