Development of fully automatic high energy x-ray tomography system at SPring-8 BL28B2

At SPring-8 BL28B2, Hoshino et al. developed a CT measurement technique using high-energy x-rays (200keV) to observe internal structures of materials. Combining this with a sample exchange robot, high-def x-ray camera, and SP8-DC computer tech, they automated the process from measurement to image reconstruction. The system captures projection images with a maximum field of view of 48mm x 1.2mm, handling larger specimens by repeated scans and stacking CT images. Measuring a sample with the size of 48mm x 10mm takes about 1.5 hours with the effective pixel size of 3.72um/pixel. Then, transferring the data to SP8-DC is completed within half an hour, and image reconstruction takes approximately 6 hours.

Authors

Publication Details

Published
2024-08-13
DOI
https://doi.org/10.1117/12.3027969
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of fully automatic high energy x-ray tomography system at SPring-8 BL28B2

Kentaro Uesugi, Toshiyuki Nishiyama, Tetsuo Honma, Masato Hoshino et al.
Advanced X-ray and CT Imaging
article

Development of fully automatic high energy x-ray tomography system at SPring-8 BL28B2

Kentaro Uesugi, Toshiyuki Nishiyama, Tetsuo Honma, Masato Hoshino, Yasumasa Joti, Jumpei Yamada, Hidekazu Takano, Takaki Hatsui, Masayuki Uesugi, Michihiro Sugahara, Makina Yabashi, Takashi Kameshima
article en

Abstract

At SPring-8 BL28B2, Hoshino et al. developed a CT measurement technique using high-energy x-rays (200keV) to observe internal structures of materials. Combining this with a sample exchange robot, high-def x-ray camera, and SP8-DC computer tech, they automated the process from measurement to image reconstruction. The system captures projection images with a maximum field of view of 48mm x 1.2mm, handling larger specimens by repeated scans and stacking CT images. Measuring a sample with the size of 48mm x 10mm takes about 1.5 hours with the effective pixel size of 3.72um/pixel. Then, transferring the data to SP8-DC is completed within half an hour, and image reconstruction takes approximately 6 hours.

Affordable and clean energy
Openalex Percentile: Top 88%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.