OpenHW3 – An open-source, low-cost temperature-controlled orbital shaker

The current lack of standardized testing methods to assess the binding isotherms of ions in cement and concrete research leads to uncontrolled variability in these results. In this study, an open-source and low-cost apparatus, named OpenHW3, is proposed to accurately measure the binding isotherms of ions in various cementitious material systems. OpenHW3 provides two main options, a temperature-controlled orbital shaker, as well as an option to retrofit a commercial orbital shaker for temperature control. The effectiveness of these device options is validated via comparison with conventional binding isotherms experiments. The binding isotherm results were comparable to conventional Waterbath shakers, while providing more reliable results compared to horizontal commercial shakers. It also provided accurate temperature control between 25 °C and 75 °C. The results here are critical for allowing open access to scientific equipment, and providing high-quality binding isotherm data for reliable service life models of urban infrastructure assets throughout the world.

Authors

Institutions

Publication Details

Journal
HardwareX
Published
2024-08-13
DOI
https://doi.org/10.1016/j.ohx.2024.e00570
Primary Topic
Concrete and Cement Materials Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

OpenHW3 – An open-source, low-cost temperature-controlled orbital shaker

Juan Pablo Gevaudan, Matthew Hollingham, Yi Xiang, Titus Reed
HardwareX
Concrete and Cement Materials Research
article

OpenHW3 – An open-source, low-cost temperature-controlled orbital shaker

Juan Pablo Gevaudan, Matthew Hollingham, Yi Xiang, Titus Reed
article en

Abstract

The current lack of standardized testing methods to assess the binding isotherms of ions in cement and concrete research leads to uncontrolled variability in these results. In this study, an open-source and low-cost apparatus, named OpenHW3, is proposed to accurately measure the binding isotherms of ions in various cementitious material systems. OpenHW3 provides two main options, a temperature-controlled orbital shaker, as well as an option to retrofit a commercial orbital shaker for temperature control. The effectiveness of these device options is validated via comparison with conventional binding isotherms experiments. The binding isotherm results were comparable to conventional Waterbath shakers, while providing more reliable results compared to horizontal commercial shakers. It also provided accurate temperature control between 25 °C and 75 °C. The results here are critical for allowing open access to scientific equipment, and providing high-quality binding isotherm data for reliable service life models of urban infrastructure assets throughout the world.

HardwareXVol. 19
Pennsylvania State University (US)
Pennsylvania State University
Affordable and clean energy
Openalex Percentile: Top 85%
Concrete and Cement Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.