Assessment of Feldkamp-Davis-Kress Reconstruction Parameters in Overall Image Quality in Cone Beam Computed Tomography

In low-dose cone beam computed tomography (CT), the insufficient number of photons inevitably results in noise, which reduces the accuracy of disease diagnosis. One approach to improving the image quality of CT images acquired using a low-dose protocol involves the utilization of a reconstruction algorithm that efficiently reduces noise. In this study, we modeled the Feldkamp–Davis–Kress (FDK) algorithm using various filters and projection angles and applied it to the reconstruction process using CT simulation. To quantitatively evaluate the quality of the reconstruction images, we measured the coefficient of variation (COV), and signal-to-noise ratio (SNR) in the air, brain, and bone regions to evaluate the noise level. Furthermore, we calculated root mean square error (RMSE), universal image quality index (UQI), and blind/referenceless image spatial quality evaluator (BRISQUE) as similarity and no-reference evaluation. The Hann filter of the FDK algorithm showed superior performance in terms of COV, SNR, RMSE, and UQI compared to the other filters. In addition, when analyzing the COV and SNR results, we observed that image quality increased significantly at projection angles smaller than approximately 2.8°. Moreover, based on BRISQUE results, we confirm that the Shepp–Logan filter exhibited the most superior performance. In conclusion, we believe that the application of the Hann filter in the FDK reconstruction process offers significant advantages in improving the image quality acquired under a low-dose protocol, and we expect that our study will be a preliminary study of no-reference evaluation of CT reconstruction images.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2024-08-12
DOI
https://doi.org/10.3390/app14167058
Citations
2
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.81
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of Feldkamp-Davis-Kress Reconstruction Parameters in Overall Image Quality in Cone Beam Computed Tomography

Jun‐Seon Choi, Ha Jin Kim, Youngjin Lee
2 citations
Applied Sciences
Medical Imaging Techniques and Applications
0.81
article

Assessment of Feldkamp-Davis-Kress Reconstruction Parameters in Overall Image Quality in Cone Beam Computed Tomography

Jun‐Seon Choi, Ha Jin Kim, Youngjin Lee
article en
2 citations

Abstract

In low-dose cone beam computed tomography (CT), the insufficient number of photons inevitably results in noise, which reduces the accuracy of disease diagnosis. One approach to improving the image quality of CT images acquired using a low-dose protocol involves the utilization of a reconstruction algorithm that efficiently reduces noise. In this study, we modeled the Feldkamp–Davis–Kress (FDK) algorithm using various filters and projection angles and applied it to the reconstruction process using CT simulation. To quantitatively evaluate the quality of the reconstruction images, we measured the coefficient of variation (COV), and signal-to-noise ratio (SNR) in the air, brain, and bone regions to evaluate the noise level. Furthermore, we calculated root mean square error (RMSE), universal image quality index (UQI), and blind/referenceless image spatial quality evaluator (BRISQUE) as similarity and no-reference evaluation. The Hann filter of the FDK algorithm showed superior performance in terms of COV, SNR, RMSE, and UQI compared to the other filters. In addition, when analyzing the COV and SNR results, we observed that image quality increased significantly at projection angles smaller than approximately 2.8°. Moreover, based on BRISQUE results, we confirm that the Shepp–Logan filter exhibited the most superior performance. In conclusion, we believe that the application of the Hann filter in the FDK reconstruction process offers significant advantages in improving the image quality acquired under a low-dose protocol, and we expect that our study will be a preliminary study of no-reference evaluation of CT reconstruction images.

Applied SciencesVol. 14(16)
Gachon University (KR)
Openalex Percentile: Top 26%
Medical Imaging Techniques and Applications
0.81
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Assessment of Feldkamp-Davis-Kress Reconstruction Parameters in Overall Image Quality in Cone Beam Computed Tomography — Jun‐Seon Choi, Ha Jin Kim, et al. · Applied Sciences (2024) | TGRS Research Map | TGRS