Study of Power Equivalent Continuous Approximation Based on the Recent Consensus Recommendations for Brain Tumor Imaging with Pulsed Chemical Exchange Saturation Transfer at 3T

The quantitative analysis of pulsed-chemical exchange saturation transfer (CEST) using a full model-based method is computationally challenging, as it involves dealing with varying RF values in pulsed saturation. A power equivalent continuous approximation of B<sub>1</sub> power was usually applied to accelerate the analysis. In line with recent consensus recommendations from the CEST community for pulsed-CEST at 3T, particularly recommending a high RF saturation power (B<sub>1</sub> = 2.0 µT) for the clinical application in brain tumors, this technical note investigated the feasibility of using average power (AP) as the continuous approximation. The simulated results revealed excellent performance of the AP continuous approximation in low saturation power scenarios, but discrepancies were observed in the z-spectra for the high saturation power cases. Cautions should be taken, or it may lead to inaccurate fitted parameters, and the difference can be more than 10% in the high saturation power cases.

Authors

Institutions

Publication Details

Journal
Magnetic Resonance in Medical Sciences
Published
2024-08-13
DOI
https://doi.org/10.2463/mrms.tn.2024-0069
Citations
1
Primary Topic
Lanthanide and Transition Metal Complexes
Type
article
Field-Weighted Citation Impact
0.12
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study of Power Equivalent Continuous Approximation Based on the Recent Consensus Recommendations for Brain Tumor Imaging with Pulsed Chemical Exchange Saturation Transfer at 3T

Chi Wei Ong, Yan Chai Hum, Wun‐She Yap, Yee Kai Tee et al.
1 citations
Magnetic Resonance in Medical Sciences
Lanthanide and Transition Metal Complexes
0.12
article

Study of Power Equivalent Continuous Approximation Based on the Recent Consensus Recommendations for Brain Tumor Imaging with Pulsed Chemical Exchange Saturation Transfer at 3T

Chi Wei Ong, Yan Chai Hum, Wun‐She Yap, Yee Kai Tee, Khin Wee Lai, Swee Qi Pan
article en
1 citations

Abstract

The quantitative analysis of pulsed-chemical exchange saturation transfer (CEST) using a full model-based method is computationally challenging, as it involves dealing with varying RF values in pulsed saturation. A power equivalent continuous approximation of B<sub>1</sub> power was usually applied to accelerate the analysis. In line with recent consensus recommendations from the CEST community for pulsed-CEST at 3T, particularly recommending a high RF saturation power (B<sub>1</sub> = 2.0 µT) for the clinical application in brain tumors, this technical note investigated the feasibility of using average power (AP) as the continuous approximation. The simulated results revealed excellent performance of the AP continuous approximation in low saturation power scenarios, but discrepancies were observed in the z-spectra for the high saturation power cases. Cautions should be taken, or it may lead to inaccurate fitted parameters, and the difference can be more than 10% in the high saturation power cases.

Magnetic Resonance in Medical SciencesVol. 24(4)
Nanyang Technological University (SG), University of Malaya (MY), Universiti Tunku Abdul Rahman (MY)
Openalex Percentile: Top 61%
Lanthanide and Transition Metal Complexes
0.12
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.