Transformer for low concentration image denoising in magnetic particle imaging

<i>Objective.</i>Magnetic particle imaging (MPI) is an emerging tracer-based<i>in vivo</i>imaging technology. The use of MPI at low superparamagnetic iron oxide nanoparticle concentrations has the potential to be a promising area of clinical application due to the inherent safety for humans. However, low tracer concentrations reduce the signal-to-noise ratio of the magnetization signal, leading to severe noise artifacts in the reconstructed MPI images. Hardware improvements have high complexity, while traditional methods lack robustness to different noise levels, making it difficult to improve the quality of low concentration MPI images.<i>Approach.</i>Here, we propose a novel deep learning method for MPI image denoising and quality enhancing based on a sparse lightweight transformer model. The proposed residual-local transformer structure reduces model complexity to avoid overfitting, in which an information retention block facilitates feature extraction capabilities for the image details. Besides, we design a noisy concentration dataset to train our model. Then, we evaluate our method with both simulated and real MPI image data.<i>Main results.</i>Simulation experiment results show that our method can achieve the best performance compared with the existing deep learning methods for MPI image denoising. More importantly, our method is effectively performed on the real MPI image of samples with an Fe concentration down to 67<i>μ</i>g<sub>Fe</sub>ml<sup>-1</sup>.<i>Significance.</i>Our method provides great potential for obtaining high quality MPI images at low concentrations.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2024-08-13
DOI
https://doi.org/10.1088/1361-6560/ad6ede
Citations
2
Primary Topic
Characterization and Applications of Magnetic Nanoparticles
Type
article
Field-Weighted Citation Impact
0.37

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transformer for low concentration image denoising in magnetic particle imaging

Zechen Wei, Yuanduo Liu, Xin Yang, Liwen Zhang et al.
2 citations
Physics in Medicine and Biology
Characterization and Applications of Magnetic Nanoparticles
0.37
article

Transformer for low concentration image denoising in magnetic particle imaging

Zechen Wei, Yuanduo Liu, Xin Yang, Liwen Zhang, Hui Hui, Jie Tian, Tan Wang
article en
2 citations

Abstract

<i>Objective.</i>Magnetic particle imaging (MPI) is an emerging tracer-based<i>in vivo</i>imaging technology. The use of MPI at low superparamagnetic iron oxide nanoparticle concentrations has the potential to be a promising area of clinical application due to the inherent safety for humans. However, low tracer concentrations reduce the signal-to-noise ratio of the magnetization signal, leading to severe noise artifacts in the reconstructed MPI images. Hardware improvements have high complexity, while traditional methods lack robustness to different noise levels, making it difficult to improve the quality of low concentration MPI images.<i>Approach.</i>Here, we propose a novel deep learning method for MPI image denoising and quality enhancing based on a sparse lightweight transformer model. The proposed residual-local transformer structure reduces model complexity to avoid overfitting, in which an information retention block facilitates feature extraction capabilities for the image details. Besides, we design a noisy concentration dataset to train our model. Then, we evaluate our method with both simulated and real MPI image data.<i>Main results.</i>Simulation experiment results show that our method can achieve the best performance compared with the existing deep learning methods for MPI image denoising. More importantly, our method is effectively performed on the real MPI image of samples with an Fe concentration down to 67<i>μ</i>g<sub>Fe</sub>ml<sup>-1</sup>.<i>Significance.</i>Our method provides great potential for obtaining high quality MPI images at low concentrations.

Physics in Medicine and BiologyVol. 69(17)
National Kidney Foundation (US), Shandong Institute of Automation (CN), Beijing Academy of Artificial Intelligence (CN), Beihang University (CN)
National Natural Science Foundation of China, Institute of Automation, Chinese Academy of Sciences, Youth Innovation Promotion Association
Openalex Percentile: Top 44%
Characterization and Applications of Magnetic Nanoparticles
0.37
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.