Impact of hydrolysis on the quantification of sulfonated acrylamide copolymers by size exclusion chromatography with <scp>UV</scp> detection

Abstract Size exclusion chromatography with UV detection (SEC‐UV) is a precise method for quantifying polyacrylamides in water. However, its accuracy can be compromised in complex matrices due to chemical degradation of the polymer. This study focuses on the impact of hydrolysis on quantifying sulfonated polyacrylamide copolymers (PAM‐AMPS) via SEC‐UV, analyzing key influencing factors. Using controlled hydrolysis, hydrolyzed copolymer (HPAM‐AMPS) standards with varying hydrolysis degree (HD) (HD = 7%–33%) were prepared without significant changes in polymer chain size. SEC‐UV analysis revealed that quantification accuracy is highly dependent on hydrolysis extent. Errors are minimal for HD up to 10%, but significantly higher for HDs of 22%–33%. Furthermore, this effect is modulated by polymer concentration. Our findings indicate that there are two compensating factors for the decrease in molar absorptivity due to amide‐to‐carboxylate substitution: the sulfonate group acting as an additional chromophore, and a redshift in absorption spectra due to hydrogen bonding at higher concentrations. This interplay between HD and concentration in this type of sulfonated polyacrylamide can help reduce quantification errors in complex aqueous samples prone to chemical degradation, like those found in environmental and subsurface applications.

Authors

Institutions

Publication Details

Journal
Journal of Applied Polymer Science
Published
2024-08-13
DOI
https://doi.org/10.1002/app.56122
Primary Topic
Environmental Chemistry and Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of hydrolysis on the quantification of sulfonated acrylamide copolymers by size exclusion chromatography with UV detection

Angela Camila Pinto Duncke, Jones Limberger, Eduardo José Creatto, Aurora Pérez‐Gramatges et al.
Journal of Applied Polymer Science
Environmental Chemistry and Analysis
article

Impact of hydrolysis on the quantification of sulfonated acrylamide copolymers by size exclusion chromatography with UV detection

Angela Camila Pinto Duncke, Jones Limberger, Eduardo José Creatto, Aurora Pérez‐Gramatges, Luís Maqueira, Cecília C. R. Gonçalves
article en

Abstract

Abstract Size exclusion chromatography with UV detection (SEC‐UV) is a precise method for quantifying polyacrylamides in water. However, its accuracy can be compromised in complex matrices due to chemical degradation of the polymer. This study focuses on the impact of hydrolysis on quantifying sulfonated polyacrylamide copolymers (PAM‐AMPS) via SEC‐UV, analyzing key influencing factors. Using controlled hydrolysis, hydrolyzed copolymer (HPAM‐AMPS) standards with varying hydrolysis degree (HD) (HD = 7%–33%) were prepared without significant changes in polymer chain size. SEC‐UV analysis revealed that quantification accuracy is highly dependent on hydrolysis extent. Errors are minimal for HD up to 10%, but significantly higher for HDs of 22%–33%. Furthermore, this effect is modulated by polymer concentration. Our findings indicate that there are two compensating factors for the decrease in molar absorptivity due to amide‐to‐carboxylate substitution: the sulfonate group acting as an additional chromophore, and a redshift in absorption spectra due to hydrogen bonding at higher concentrations. This interplay between HD and concentration in this type of sulfonated polyacrylamide can help reduce quantification errors in complex aqueous samples prone to chemical degradation, like those found in environmental and subsurface applications.

Journal of Applied Polymer ScienceVol. 141(43)
Pontifícia Universidade Católica do Rio de Janeiro (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro, Agência Nacional do Petróleo, Gás Natural e Biocombustíveis
Clean water and sanitation
Openalex Percentile: Top 89%
Environmental Chemistry and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.