Detection of lymphoma biomarker ferritin using functionalized carbon nanotube platform

For the detection of ferritin, this work engineered an electrochemical immunosensor by functionalizing multi-walled carbon nanotubes (MWCNTs) and integrating them into a screen-printed carbon electrode (SPCE) platform. Under optimal conditions (pH 7.4, antibody concentration 10 μg/mL, incubation time 30 min), the developed immunosensor exhibited a linear relationship between the electrochemical signal and ferritin concentrations spanning 1–500 ng/mL. Notably, it demonstrated an impressive ability to detect ferritin at exceptionally low levels, with a limit of detection reaching 0.3 ng/mL. The immunosensor demonstrated high selectivity, good reproducibility (RSD = 3.2 %, n = 5), and stability (87.3 % of initial response after 14 days at 4°C). The immunosensor was used to sensing ferritin in serum and good agreement with the commercial ELISA method (relative error < 5 %). The proposed sensor shows promise as a analytical approach for early diagnosis of lymphoma and point-of-care testing.

Authors

Institutions

Publication Details

Journal
Alexandria Engineering Journal
Published
2024-08-13
DOI
https://doi.org/10.1016/j.aej.2024.07.133
Citations
2
Primary Topic
MicroRNA in disease regulation
Type
article
Field-Weighted Citation Impact
0.57
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detection of lymphoma biomarker ferritin using functionalized carbon nanotube platform

Xiaoling Guo, Shuang Qu, Sicong Jiang, Biyun Chen et al.
2 citations
Alexandria Engineering Journal
MicroRNA in disease regulation
0.57
article

Detection of lymphoma biomarker ferritin using functionalized carbon nanotube platform

Xiaoling Guo, Shuang Qu, Sicong Jiang, Biyun Chen, Zhihai Zheng, Chen Wang
article en
2 citations

Abstract

For the detection of ferritin, this work engineered an electrochemical immunosensor by functionalizing multi-walled carbon nanotubes (MWCNTs) and integrating them into a screen-printed carbon electrode (SPCE) platform. Under optimal conditions (pH 7.4, antibody concentration 10 μg/mL, incubation time 30 min), the developed immunosensor exhibited a linear relationship between the electrochemical signal and ferritin concentrations spanning 1–500 ng/mL. Notably, it demonstrated an impressive ability to detect ferritin at exceptionally low levels, with a limit of detection reaching 0.3 ng/mL. The immunosensor demonstrated high selectivity, good reproducibility (RSD = 3.2 %, n = 5), and stability (87.3 % of initial response after 14 days at 4°C). The immunosensor was used to sensing ferritin in serum and good agreement with the commercial ELISA method (relative error < 5 %). The proposed sensor shows promise as a analytical approach for early diagnosis of lymphoma and point-of-care testing.

Alexandria Engineering JournalVol. 104
Fujian Medical University (CN), Sun Yat-sen University (CN), University Hospital of Geneva (CH), The First Affiliated Hospital, Sun Yat-sen University (CN), Fujian Provincial Hospital (CN), Geneva College (US)
Zero hunger
Openalex Percentile: Top 32%
MicroRNA in disease regulation
0.57
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detection of lymphoma biomarker ferritin using functionalized carbon nanotube platform — Xiaoling Guo, Shuang Qu, et al. · Alexandria Engineering Journal (2024) | TGRS Research Map | TGRS