Oxidized Ethylene Glycol/ZrO<sub>2</sub>-coated NiTi Orthodontic Arch Wires: Surface Characterization and Electrochemical and Corrosion Studies

Background: Orthodontic arch wires, typically made of Nickel Titanium (NiTi), are widely utilized in dental procedures for correcting teeth misalignment and jaw issues due to their favorable mechanical attributes and cost-effectiveness. However, these NiTi wires are prone to corrosion in the oral environment, leading to diminished mechanical stability, compromised aesthetics, and potential health concerns for patients. Objective: There is a growing demand to augment the corrosion resistance and stability of orthodontic wires. Hence, this study aimed to address these issues. Herein, zirconium dioxide (ZrO2) and oxidized ethylene glycol (OEG) films were deposited onto NiTi wires to improve the corrosion resistance and stability. Methods: NiTi wires were modified by a two-step process involving electrodeposition of ZrO2 and oxidized ethylene glycol (OEG) film. The surface characterizations of coated material (OEG/ZrO2/NiTi) were carried out by using Field Emission Scanning Electron Microscopy (FESEM), Energy Dispersive X-ray Spectroscopy (EDS), and Electron Microprobe Analysis (EMap) to confirm the elemental composition of the coated NiTi wire. Results: The OEG/ZrO2/NiTi wire exhibited a potentiodynamic polarization resistance of 547037 Ω and higher stability than the bare NiTi wire (396421 Ω). The corrosion rate for OEG/ZrO2/NiTi wire was found to be 0.040 mm/year, which was comparatively lower than a bare NiTi wire (0.069 mm/year). Due to the formation of OEG/ZrO2 film, NiTi wire became electrically insulative and showed a higher impedance than bare NiTi wire. Conclusion: The bilayer coating of ZrO2 and OEG has proven to significantly improve the corrosion resistance and stability of the wires. Thus, these materials can be considered for coating orthodontic arch wires with improved corrosion stability.

Authors

Institutions

Publication Details

Journal
Current Nanoscience
Published
2024-08-12
DOI
https://doi.org/10.2174/0115734137313324240723073001
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Oxidized Ethylene Glycol/ZrO2-coated NiTi Orthodontic Arch Wires: Surface Characterization and Electrochemical and Corrosion Studies

Dhanraj Ganapathy, Ashok Kumar Sundramoorthy, Gokul Sridharan, Keerthana Madhivanan et al.
Current Nanoscience
Dental materials and restorations
article

Oxidized Ethylene Glycol/ZrO2-coated NiTi Orthodontic Arch Wires: Surface Characterization and Electrochemical and Corrosion Studies

Dhanraj Ganapathy, Ashok Kumar Sundramoorthy, Gokul Sridharan, Keerthana Madhivanan, Abisha Perumal
article en

Abstract

Background: Orthodontic arch wires, typically made of Nickel Titanium (NiTi), are widely utilized in dental procedures for correcting teeth misalignment and jaw issues due to their favorable mechanical attributes and cost-effectiveness. However, these NiTi wires are prone to corrosion in the oral environment, leading to diminished mechanical stability, compromised aesthetics, and potential health concerns for patients. Objective: There is a growing demand to augment the corrosion resistance and stability of orthodontic wires. Hence, this study aimed to address these issues. Herein, zirconium dioxide (ZrO2) and oxidized ethylene glycol (OEG) films were deposited onto NiTi wires to improve the corrosion resistance and stability. Methods: NiTi wires were modified by a two-step process involving electrodeposition of ZrO2 and oxidized ethylene glycol (OEG) film. The surface characterizations of coated material (OEG/ZrO2/NiTi) were carried out by using Field Emission Scanning Electron Microscopy (FESEM), Energy Dispersive X-ray Spectroscopy (EDS), and Electron Microprobe Analysis (EMap) to confirm the elemental composition of the coated NiTi wire. Results: The OEG/ZrO2/NiTi wire exhibited a potentiodynamic polarization resistance of 547037 Ω and higher stability than the bare NiTi wire (396421 Ω). The corrosion rate for OEG/ZrO2/NiTi wire was found to be 0.040 mm/year, which was comparatively lower than a bare NiTi wire (0.069 mm/year). Due to the formation of OEG/ZrO2 film, NiTi wire became electrically insulative and showed a higher impedance than bare NiTi wire. Conclusion: The bilayer coating of ZrO2 and OEG has proven to significantly improve the corrosion resistance and stability of the wires. Thus, these materials can be considered for coating orthodontic arch wires with improved corrosion stability.

Current NanoscienceVol. 21(5)
Saveetha University (IN)
Affordable and clean energy
Openalex Percentile: Top 85%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.