Machine learning-based optimization and performance analysis of cooling towers

In the present study, a machine learning technique was employed to select parameters and optimize the performance of a cooling tower used in a building. Input parameters and the output response values have been selected in an unstructured and structured manner. Air velocity, water flow rate and nanoparticle concentration have been considered as the input variables whereas range, cooling efficiency and energy consumption are the output variables. A Central Composite design (CCD) based technique has been adopted to structure the input-output relations. A multilayer perceptron-based ANN model has been built using both unstructured and structured combinations of data points. PSO optimization has been performed by creating the objective functions from the developed ANN models. Optimum results obtained by using the structured combination are better than those obtained by the unstructured combination. Optimum cooling tower performance was noticed for an air velocity of 14.67 m/s, water flow rate of 3.87 LPM and nanoparticle volume concentration of 1.84 vol (%).

Authors

Institutions

Publication Details

Journal
Journal of Building Engineering
Published
2024-08-12
DOI
https://doi.org/10.1016/j.jobe.2024.110415
Citations
10
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
2.13
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine learning-based optimization and performance analysis of cooling towers

Shiva Kumar, A. Ganesha, Sampath Suranjan Salins, S.V. Kota Reddy
10 citations
Journal of Building Engineering
Adsorption and Cooling Systems
2.13
article

Machine learning-based optimization and performance analysis of cooling towers

Shiva Kumar, A. Ganesha, Sampath Suranjan Salins, S.V. Kota Reddy
article en
10 citations

Abstract

In the present study, a machine learning technique was employed to select parameters and optimize the performance of a cooling tower used in a building. Input parameters and the output response values have been selected in an unstructured and structured manner. Air velocity, water flow rate and nanoparticle concentration have been considered as the input variables whereas range, cooling efficiency and energy consumption are the output variables. A Central Composite design (CCD) based technique has been adopted to structure the input-output relations. A multilayer perceptron-based ANN model has been built using both unstructured and structured combinations of data points. PSO optimization has been performed by creating the objective functions from the developed ANN models. Optimum results obtained by using the structured combination are better than those obtained by the unstructured combination. Optimum cooling tower performance was noticed for an air velocity of 14.67 m/s, water flow rate of 3.87 LPM and nanoparticle volume concentration of 1.84 vol (%).

Journal of Building EngineeringVol. 96
Manipal Academy of Higher Education (IN), VIT-AP University
Sustainable cities and communities
Openalex Percentile: Top 14%
Adsorption and Cooling Systems
2.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.