Optimizing Image Quality with High-Resolution, Deep-Learning-Based Diffusion-Weighted Imaging in Breast Cancer Patients at 1.5 T
The objective of this study was to evaluate a high-resolution deep-learning (DL)-based diffusion-weighted imaging (DWI) sequence for breast magnetic resonance imaging (MRI) in comparison to a standard DWI sequence (DWI<sub>Std</sub>) at 1.5 T. It is a prospective study of 38 breast cancer patients, who were scanned with DWI<sub>Std</sub> and DWI<sub>DL</sub>. Both DWI sequences were scored for image quality, sharpness, artifacts, contrast, noise, and diagnostic confidence with a Likert-scale from 1 (non-diagnostic) to 5 (excellent). The lesion diameter was evaluated on b 800 DWI, apparent diffusion coefficient (ADC), and the second subtraction (SUB) of the contrast-enhanced T1 VIBE. SNR was also calculated. Statistics included correlation analyses and paired <i>t</i>-tests. High-resolution DWI<sub>DL</sub> offered significantly superior image quality, sharpness, noise, contrast, and diagnostic confidence (each <i>p</i> < 0.02)). Artifacts were significantly higher in DWI<sub>DL</sub> by one reader (M = 4.62 vs. 4.36 Likert scale, <i>p</i> < 0.01) without affecting the diagnostic confidence. SNR was higher in DWI<sub>DL</sub> for b 50 and ADC maps (each <i>p</i> = 0.07). Acquisition time was reduced by 22% in DWI<sub>DL</sub>. The lesion diameters in DWI b 800<sub>DL</sub> and <sub>Std</sub> and ADC<sub>DL</sub> and <sub>Std</sub> were respectively 6% lower compared to the 2nd SUB. A DL-based diffusion sequence at 1.5 T in breast MRI offers a higher resolution and a faster acquisition, including only minimally more artefacts without affecting the diagnostic confidence.
Authors
- Thomas Benkert (ORCID: https://orcid.org/0000-0002-3794-5580)
- Konstantin Nikolaou (ORCID: https://orcid.org/0000-0003-2668-7325)
- Daniel Wessling (ORCID: https://orcid.org/0009-0009-3390-8027)
- Susann-Cathrin Olthof (ORCID: https://orcid.org/0000-0002-3345-8750)
- Daniel Leyhr (ORCID: https://orcid.org/0000-0003-0436-0866)
- Saif Afat (ORCID: https://orcid.org/0000-0002-6861-6245)
- Elisabeth Weiland (ORCID: https://orcid.org/0000-0001-7517-1291)
- Heike Preibsch (ORCID: https://orcid.org/0000-0002-8800-3788)
Institutions
- Heidelberg University (DE)
- University Hospital Heidelberg (DE)
- Siemens Healthineers (Germany) (DE)
- University of Tübingen (DE)
Publication Details
- Journal
- Diagnostics
- Published
- 2024-08-10
- DOI
- https://doi.org/10.3390/diagnostics14161742
- Citations
- 3
- Primary Topic
- MRI in cancer diagnosis
- Type
- article
- Field-Weighted Citation Impact
- 1.21