Optimization design and simulation of chip-level micro-gas columnar preconcentrator structure based on ANSYS

Abstract To achieve the efficient preconcentration of measured sample gas in microfluidic chips, this paper proposes a design and simulation scheme for the chip-level micro-gas columnar pre-concentrated structure based on ANSYS software. Firstly, four kinds of chip-level micro-gas columnar preconcentrators with circular, semi-circular, triangular, and rhombic shapes were designed, and the simulation analysis of gas-phase micro-fluidic dynamics was performed on the chip-level micro-gas columnar preconcentrator by ANSYS software. The influence of different design parameters on the pre-concentrated effect of level chips micro-gas columnar preconcentrator was discussed. The simulation results show that the arrangement is a triangle arranged in reverse parallel, and the preconcentration effect of the chip-level micro gas column preconcentrator is better.

Authors

Institutions

Publication Details

Journal
Journal of Physics Conference Series
Published
2024-08-01
DOI
https://doi.org/10.1088/1742-6596/2816/1/012079
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization design and simulation of chip-level micro-gas columnar preconcentrator structure based on ANSYS

Yunzheng Ran, Luoping Lu, Jianwei Zhong, Xiangpeng Tian et al.
Journal of Physics Conference Series
Gas Sensing Nanomaterials and Sensors
article

Optimization design and simulation of chip-level micro-gas columnar preconcentrator structure based on ANSYS

Yunzheng Ran, Luoping Lu, Jianwei Zhong, Xiangpeng Tian, Honghua Liao, Ronghao Zheng
article en

Abstract

Abstract To achieve the efficient preconcentration of measured sample gas in microfluidic chips, this paper proposes a design and simulation scheme for the chip-level micro-gas columnar pre-concentrated structure based on ANSYS software. Firstly, four kinds of chip-level micro-gas columnar preconcentrators with circular, semi-circular, triangular, and rhombic shapes were designed, and the simulation analysis of gas-phase micro-fluidic dynamics was performed on the chip-level micro-gas columnar preconcentrator by ANSYS software. The influence of different design parameters on the pre-concentrated effect of level chips micro-gas columnar preconcentrator was discussed. The simulation results show that the arrangement is a triangle arranged in reverse parallel, and the preconcentration effect of the chip-level micro gas column preconcentrator is better.

Journal of Physics Conference SeriesVol. 2816(1)
Minzu University of China (CN)
Openalex Percentile: Top 90%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.