Optimization design and simulation of chip-level micro-gas columnar preconcentrator structure based on ANSYS
Abstract To achieve the efficient preconcentration of measured sample gas in microfluidic chips, this paper proposes a design and simulation scheme for the chip-level micro-gas columnar pre-concentrated structure based on ANSYS software. Firstly, four kinds of chip-level micro-gas columnar preconcentrators with circular, semi-circular, triangular, and rhombic shapes were designed, and the simulation analysis of gas-phase micro-fluidic dynamics was performed on the chip-level micro-gas columnar preconcentrator by ANSYS software. The influence of different design parameters on the pre-concentrated effect of level chips micro-gas columnar preconcentrator was discussed. The simulation results show that the arrangement is a triangle arranged in reverse parallel, and the preconcentration effect of the chip-level micro gas column preconcentrator is better.
Authors
- Yunzheng Ran
- Luoping Lu
- Jianwei Zhong (ORCID: https://orcid.org/0000-0003-2644-2184)
- Xiangpeng Tian
- Honghua Liao
- Ronghao Zheng
Institutions
- Minzu University of China (CN)
Publication Details
- Journal
- Journal of Physics Conference Series
- Published
- 2024-08-01
- DOI
- https://doi.org/10.1088/1742-6596/2816/1/012079
- Primary Topic
- Gas Sensing Nanomaterials and Sensors
- Type
- article
- Field-Weighted Citation Impact
- 0.00